New Zealand Β· costs in NZD
Reverse cycle window / wall air conditioner
Gree GJH12AG-K6DRNG1A Heat Pump
Gree GJH12AG-K6DRNG1A is a 3.6 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7630).
- Energy rating (cooling)
- 2
- Heating: 0.5
- Annual electricity use
- 2,522 kWh
- 247 cooling + 2,275 heating
- Estimated running cost
- $832 / year
- $69 / month Β· $8,323 over 10 years
- Capacity
- 3.6 kW cooling
- 3.5 kW heating
9% more electricity than the median of 15 comparable 3.5 kW reverse cycle window / wall registrations (2,316 kWh a year) in the cold zone. Uses less than 0% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 68% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Gree GJH12AG-K6DRNG1A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,522 | $832 | $8,323 |
| Mixed zone | 1,239 | $409 | $4,089 |
| Hot zone | 1,203 | $397 | $3,970 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 3.6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MWFI36H3.5 kW heating3.6 kW cooling2,030 kWh/yr | 2.5 | $670 | |
| Midea MWFF39H3.5 kW heating3.9 kW cooling2,316 kWh/yr | 2 | $764 | |
| Westinghouse WWH39HWC3.5 kW heating3.9 kW cooling2,316 kWh/yr | 2 | $764 | |
| Kaden KW123.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| TECO TWW40HFWDG3.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 |
Heat pumps similar to the Gree GJH12AG-K6DRNG1A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TWW36HVAG3.5 kW heating3.6 kW cooling2,522 kWh/yr | 2 | $832 | |
| Midea MWFI36H3.5 kW heating3.6 kW cooling2,030 kWh/yr | 2.5 | $670 | |
| Westinghouse WWH39HWC3.5 kW heating3.9 kW cooling2,316 kWh/yr | 2 | $764 | |
| TECO TWW40HFWDG3.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Westinghouse WWH39HWA3.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Kelvinator KWH39HRF3.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Kaden KW123.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Midea MWFF39H3.5 kW heating3.9 kW cooling2,316 kWh/yr | 2 | $764 |
Compare GJH12AG-K6DRNG1A with another model
Gree GJH12AG-K6DRNG1A specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 3.60 kW
- Cooling power input
- 1.08 kW
- Rated heating capacity (7 Β°C)
- 3.50 kW
- Heating power input
- 1.06 kW
- EER, full load (tested)
- 3.47
- COP, full load (tested)
- 3.33
- Rated AEER
- 3.27
- Rated ACOP
- 3.24
- Standby power (PIA)
- 4.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 63.9 dB(A)
- Outdoor sound power
- 69.5 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Gree GJH12AG-K6DRNG1A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 490 | 625 |
| Coldresidential | residential | 2.0 | 0.5 | 247 | 2,275 |
| Mixedcommercial | commercial | β | β | 625 | 321 |
| Mixedresidential | residential | 2.0 | 0.5 | 377 | 862 |
| Hotcommercial | commercial | β | β | 1,476 | 59 |
| Hotresidential | residential | 2.5 | 1.5 | 1,108 | 95 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 325 W
- h__h2_ext_cap_power_rated
- 915 W
- c__t1_half_cap_power_rated
- 475 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 435 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 2020 W
- h__h1_half_cap_heat_cap_rated
- 1750 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 280 W
- c__t1_min_cap_cooling_cap_rated
- 1300 W
- c__low_temp_full_cap_power_rated
- 991.69 W
- c__low_temp_half_cap_power_rated
- 434.15000000000003 W
- c__t1_half_cap_cooling_cap_rated
- 1800 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 1480 W
- c__low_temp_full_cap_cooling_cap_rated
- 3877.2 W
- c__low_temp_half_cap_cooling_cap_rated
- 1938.6 W
Other model numbers on registration AAC7630
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7630
- GEMS registration id
- 155482
- Status
- approved, available (self-reported)
- Registration expires
- 16 July 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- GJH12AG-K6DRNG1A
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5