Reverse cycle window / wall air conditioner
Gree GJH18AH-K6DRNB3A Heat Pump
Gree GJH18AH-K6DRNB3A is a 5.3 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7697).
- Energy rating (cooling)
- 2.5
- Heating: 1.5
- Annual electricity use
- 2,357 kWh
- 356 cooling + 2,001 heating
- Estimated running cost
- $778 / year
- $65 / month Β· $7,778 over 10 years
- Capacity
- 5.3 kW cooling
- 4.8 kW heating
26% less electricity than the median of 6 comparable 5 kW reverse cycle window / wall registrations (3,192 kWh a year) in the cold zone. Uses less than 67% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 71% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Gree GJH18AH-K6DRNB3A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,357 | $778 | $7,778 |
| Mixed zone | 1,304 | $430 | $4,303 |
| Hot zone | 1,742 | $575 | $5,749 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps similar to the Gree GJH18AH-K6DRNB3A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TWW53HFWDG4.8 kW heating5.3 kW cooling3,193 kWh/yr | 1.5 | $1,054 | |
| TECO TWW53HVAG4.8 kW heating5.3 kW cooling2,357 kWh/yr | 2.5 | $778 | |
| Kaden KW184.8 kW heating5.3 kW cooling3,193 kWh/yr | 1.5 | $1,054 | |
| Midea MWFF53H4.8 kW heating5.4 kW cooling3,190 kWh/yr | 1.5 | $1,053 |
Other Gree models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GJH18AE-K6NRNG1A4.8 kW heating5.3 kW cooling3,193 kWh/yr | 1.5 | $1,054 | |
| Gree GJH18AE-K6NRNB3A4.8 kW heating5.3 kW cooling3,193 kWh/yr | 1.5 | $1,054 |
Compare GJH18AH-K6DRNB3A with another model
Gree GJH18AH-K6DRNB3A specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 5.30 kW
- Cooling power input
- 1.60 kW
- Rated heating capacity (7 Β°C)
- 4.80 kW
- Heating power input
- 1.40 kW
- EER, full load (tested)
- 3.45
- COP, full load (tested)
- 3.76
- Rated AEER
- 3.28
- Rated ACOP
- 3.39
- Standby power (PIA)
- 4.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64.9 dB(A)
- Outdoor sound power
- 69.2 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Gree GJH18AH-K6DRNB3A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 689 | 650 |
| Coldresidential | residential | 2.5 | 1.5 | 356 | 2,001 |
| Mixedcommercial | commercial | β | β | 890 | 345 |
| Mixedresidential | residential | 2.5 | 1.5 | 544 | 760 |
| Hotcommercial | commercial | β | β | 2,155 | 76 |
| Hotresidential | residential | 2.5 | 2.0 | 1,624 | 118 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 480 W
- h__h2_ext_cap_power_rated
- 1400 W
- c__t1_half_cap_power_rated
- 700 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 600 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 4000 W
- h__h1_half_cap_heat_cap_rated
- 2450 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 410 W
- c__t1_min_cap_cooling_cap_rated
- 1770 W
- c__low_temp_full_cap_power_rated
- 1462.4 W
- c__low_temp_half_cap_power_rated
- 639.8000000000001 W
- c__t1_half_cap_cooling_cap_rated
- 2600 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 2200 W
- c__low_temp_full_cap_cooling_cap_rated
- 5708.099999999999 W
- c__low_temp_half_cap_cooling_cap_rated
- 2800.2 W
Other model numbers on registration AAC7697
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7697
- GEMS registration id
- 155484
- Status
- approved, available (self-reported)
- Registration expires
- 12 August 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- GJH18AH-K6DRNG1A
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.