c/kWh
Energy rating (cooling)
1
Heating: 1.5
Annual electricity use
6,484 kWh
1,095 cooling + 5,389 heating
Estimated running cost
$2,140 / year
$178 / month Β· $21,397 over 10 years
Capacity
12.1 kW cooling
14 kW heating

8% more electricity than the median of 7 comparable 12.5 kW reverse cycle ducted multi-split / vrf registrations (6,009 kWh a year) in the cold zone. Uses less than 29% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 28% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree GMV-Y120WL running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,484$2,140$21,397
Mixed zone 3,856$1,272$12,725
Hot zone 4,818$1,590$15,899

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Samsung Electronics AM040KXMDEH/EU/ AM036ANLDKH / AM045ANLDKH12.1 kW heating12.1 kW cooling5,623 kWh/yr1.5$1,856
Samsung Electronics AM040NXMDER/EU12.1 kW heating12.1 kW cooling5,738 kWh/yr1.5$1,894
Midea MDV-V120WHN8(At)14 kW heating12.3 kW cooling6,009 kWh/yr2.5$1,983

Heat pumps similar to the Gree GMV-Y120WL

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Samsung Electronics AM040KXMDEH/EU/ AM036ANLDKH / AM045ANLDKH12.1 kW heating12.1 kW cooling5,623 kWh/yr1.5$1,856
Samsung Electronics AM040NXMDER/EU12.1 kW heating12.1 kW cooling5,738 kWh/yr1.5$1,894
Midea MDV-V120WHN8(At)14 kW heating12.3 kW cooling6,009 kWh/yr2.5$1,983
Haier AU042FPERA14.2 kW heating12.6 kW cooling6,989 kWh/yr2$2,306

Other Gree models of similar capacity

ModelStarsEst. cost / yrCompare
Gree GMV-120WL/A-T(A)14 kW heating12.1 kW cooling7,146 kWh/yr1.5$2,358

Compare GMV-Y120WL/A-T(A) with another model

Gree GMV-Y120WL specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.10 kW
Cooling power input
3.85 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.60 kW
EER, full load (tested)
3.15
COP, full load (tested)
3.98
Rated AEER
2.98
Rated ACOP
3.67
Standby power (PIA)
62.2 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
73.2 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree GMV-Y120WL zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,2361,877
Coldresidential1.01.51,0955,389
Mixedcommercial––2,7461,076
Mixedresidential1.02.01,6262,230
Hotcommercial––5,803320
Hotresidential2.02.04,355463
Part-load test points (20 values)
h__h2_ext_cap_power_rated
5300 W
c__t1_half_cap_power_rated
1700 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1700 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
15000 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3518.9 W
c__low_temp_half_cap_power_rated
1553.8 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
13031.699999999999 W
c__low_temp_half_cap_cooling_cap_rated
6462 W

New Zealand E3 registration details

Registration number
AAC8615
GEMS registration id
167466
Status
approved, available (self-reported)
Registration expires
19 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20