New Zealand Β· costs in NZD
Reverse cycle split system air conditioner, cassette
Gree GUD100W1/NhC-S / GUD100T1/C-S Heat Pump
Gree GUD100W1/NhC-S / GUD100T1/C-S is a 10 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7698).
A newer registration of this model exists: AAC8138.
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 4,972 kWh
- 490 cooling + 4,482 heating
- Estimated running cost
- $1,641 / year
- $137 / month Β· $16,408 over 10 years
- Capacity
- 10 kW cooling
- 12 kW heating
12% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 15% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Gree running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,972 | $1,641 | $16,408 |
| Mixed zone | 2,332 | $770 | $7,696 |
| Hot zone | 2,555 | $843 | $8,432 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Kogan KASSSAC90HE9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90H*9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 |
Heat pumps similar to the Gree
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr | 3.5 | $1,320 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr | 3.5 | $1,320 | |
| Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr | 4 | $1,251 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling4,455 kWh/yr | 4 | $1,470 | |
| Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling4,244 kWh/yr | 3 | $1,401 |
Compare GUD100W1/NhC-S / GUD100T1/C-S with another model
Gree specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.90 kW
- Rated heating capacity (7 Β°C)
- 12.00 kW
- Heating power input
- 3.45 kW
- EER, full load (tested)
- 3.42
- COP, full load (tested)
- 3.41
- Rated AEER
- 3.44
- Rated ACOP
- 3.47
- Standby power (PIA)
- 3.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 65.1 dB(A)
- Outdoor sound power
- 72 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Gree zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 362 | 1,330 |
| Coldresidential | residential | 4.0 | 2.0 | 490 | 4,482 |
| Mixedcommercial | commercial | β | β | 691 | 654 |
| Mixedresidential | residential | 3.5 | 2.5 | 764 | 1,568 |
| Hotcommercial | commercial | β | β | 2,685 | 127 |
| Hotresidential | residential | 4.0 | 3.5 | 2,351 | 204 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 530 W
- h__h1_min_cap_power_rated
- 535 W
- h__h2_ext_cap_power_rated
- 3600 W
- c__t1_half_cap_power_rated
- 1020 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1150 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2850 W
- h__h2_ext_cap_heat_cap_rated
- 9600 W
- h__h1_half_cap_heat_cap_rated
- 6000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 290 W
- c__t1_min_cap_cooling_cap_rated
- 2100 W
- c__low_temp_full_cap_power_rated
- 2650.6 W
- c__low_temp_half_cap_power_rated
- 932.2800000000001 W
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 1950 W
- c__low_temp_full_cap_cooling_cap_rated
- 10770 W
- c__low_temp_half_cap_cooling_cap_rated
- 5385 W
Related Gree model numbers starting with GUD100W1NHCSGUD100T1CS
2 model numbers on 2 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.
| Model | Registration | Stars | kWh / yr | Registration expires |
|---|---|---|---|---|
| GUD100W1/NhC-S / GUD100T1/C-S | AAC8034 | 3.5 | 5,011 | 31 January 2029 |
| GUD100W1/NhC-S / GUD100T1/C-S | AAC8138 | 4 | 4,976 | 25 March 2029 |
New Zealand E3 registration details
- Registration number
- AAC7698
- GEMS registration id
- 155491
- Status
- approved, available (self-reported)
- Registration expires
- 12 August 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.