c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
1,266 kWh
119 cooling + 1,147 heating
Estimated running cost
$418 / year
$35 / month Β· $4,178 over 10 years
Capacity
2 kW cooling
2.6 kW heating

53% more electricity than the median of 63 comparable 2 kW reverse cycle split system registrations (829 kWh a year) in the cold zone. Uses less than 5% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 85% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,266$418$4,178
Mixed zone 582$192$1,921
Hot zone 590$195$1,947

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
TCL TAC-06CSHD/*IH1.8 kW heating1.8 kW cooling630 kWh/yr3.5$208
TCL TAC-06CHSD/VEIH1.8 kW heating1.8 kW cooling630 kWh/yr3.5$208
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr5.5$234
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr5.5$237

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRG020N8/42QRG020N82.2 kW heating2 kW cooling734 kWh/yr5$242
Mitsubishi Heavy Industries SRC20ZSXA-W / SRK20ZSXA-W2.7 kW heating2 kW cooling749 kWh/yr4.5$247
Mitsubishi Heavy Industries SRC20ZSXA-W/SRK20ZSXA-WF2.7 kW heating2 kW cooling751 kWh/yr4.5$248
Kaden KSI062.3 kW heating2 kW cooling718 kWh/yr5.5$237
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr5.5$234
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr5.5$237
Carrier 38QHG020N8/42QHG020N8-12.2 kW heating2 kW cooling734 kWh/yr5$242
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr5.5$237

Compare GWH07ATAXA-K6DNA1D/O / GWH07ATAXA-K6DNA1D/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.00 kW
Cooling power input
0.54 kW
Rated heating capacity (7 Β°C)
2.64 kW
Heating power input
0.68 kW
EER, full load (tested)
3.72
COP, full load (tested)
3.91
Rated AEER
3.67
Rated ACOP
3.87
Standby power (PIA)
1.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55.6 dB(A)
Outdoor sound power
57.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––206356
Coldresidential3.01.51191,147
Mixedcommercial––288179
Mixedresidential3.02.0183399
Hotcommercial––66637
Hotresidential3.02.553258
Part-load test points (20 values)
h__h1_min_cap_power_rated
188 W
h__h2_ext_cap_power_rated
1100 W
c__t1_half_cap_power_rated
255 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
288 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
770 W
h__h2_ext_cap_heat_cap_rated
2100 W
h__h1_half_cap_heat_cap_rated
1260 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
186 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
990 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
970 W

New Zealand E3 registration details

Registration number
AAC8667
GEMS registration id
168147
Status
approved, available (self-reported)
Registration expires
23 March 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.