c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
13,589 kWh
1,906 cooling + 11,683 heating
Estimated running cost
$4,484 / year
$374 / month Β· $44,844 over 10 years
Capacity
28 kW cooling
28 kW heating

2% more electricity than the median of 32 comparable 25 kW reverse cycle multi-split / vrf registrations (13,318 kWh a year) in the cold zone. Uses less than 44% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 10% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Haier AU10NFKERA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 13,589$4,484$44,844
Mixed zone 7,589$2,504$25,044
Hot zone 9,192$3,033$30,334

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 28 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-10MF3R731.5 kW heating28 kW cooling10,115 kWh/yr4$3,338
Panasonic U-10LZ2E828 kW heating28 kW cooling10,775 kWh/yr2.5$3,556
Daikin REYA10AYM31.5 kW heating28 kW cooling11,678 kWh/yr3$3,854
Mitsubishi Heavy Industries FDC280KXZME128 kW heating28 kW cooling11,787 kWh/yr2.5$3,890
Mitsubishi Heavy Industries FDC280KXZPE128 kW heating28 kW cooling11,791 kWh/yr2.5$3,891

Heat pumps similar to the Haier AU10NFKERA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-10MF3R731.5 kW heating28 kW cooling10,115 kWh/yr4$3,338
Hitachi RAS-100RNCBLW31.5 kW heating28 kW cooling12,697 kWh/yr2$4,190
Toshiba MMY-MUP1001FT8P-A28 kW heating28 kW cooling12,564 kWh/yr4$4,146
Panasonic U-10LZ2E828 kW heating28 kW cooling10,775 kWh/yr2.5$3,556
Mitsubishi Heavy Industries FDC280KXZPE128 kW heating28 kW cooling11,791 kWh/yr2.5$3,891
Mitsubishi Heavy Industries FDC280KXZME128 kW heating28 kW cooling11,787 kWh/yr2.5$3,890
Daikin REYA10AYM31.5 kW heating28 kW cooling11,678 kWh/yr3$3,854
Toshiba MMY-MUP10S1HT8P-A31.5 kW heating28 kW cooling12,641 kWh/yr3$4,172

Compare AU10NFKERA with another model

Haier AU10NFKERA specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
28.00 kW
Cooling power input
8.48 kW
Rated heating capacity (7 Β°C)
28.00 kW
Heating power input
8.24 kW
EER, full load (tested)
3.32
COP, full load (tested)
3.42
Rated AEER
3.24
Rated ACOP
3.33
Standby power (PIA)
49.7 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
64 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Haier AU10NFKERA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,0763,915
Coldresidential2.01.51,90611,683
Mixedcommercial––5,1052,153
Mixedresidential2.01.52,9464,643
Hotcommercial––11,235517
Hotresidential2.52.08,405787
Part-load test points (16 values)
h__h2_ext_cap_power_rated
8000 W
c__t1_half_cap_power_rated
3200 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
3650 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
25000 W
h__h1_half_cap_heat_cap_rated
14000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
14000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10093
GEMS registration id
179033
Status
approved, available (self-reported)
Registration expires
17 October 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: haierhome.com.au. How the derived figures are calculated.