c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
2,775 kWh
282 cooling + 2,493 heating
Estimated running cost
$916 / year
$76 / month Β· $9,158 over 10 years
Capacity
6 kW cooling
7.5 kW heating

2% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 38% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,775$916$9,158
Mixed zone 1,315$434$4,340
Hot zone 1,384$457$4,567

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hyundai HYSSSAC53TB5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/UB5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Heat pumps similar to the Hitachi

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr3.5$686
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr3.5$687
Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr0$723
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD26.8 kW heating6 kW cooling2,490 kWh/yr4.5$822
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Daikin RXM60AVMA / FTXM60AVMA7.2 kW heating6 kW cooling2,420 kWh/yr5$799
Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGKD26.8 kW heating6 kW cooling2,490 kWh/yr4.5$822

Compare PAS-2.5UFASNQ1 / PCI-2.5UFA1NQ with another model

Hitachi specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
6.00 kW
Cooling power input
1.44 kW
Rated heating capacity (7 Β°C)
7.50 kW
Heating power input
1.69 kW
EER, full load (tested)
4.30
COP, full load (tested)
4.52
Rated AEER
4.09
Rated ACOP
4.36
Standby power (PIA)
9.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––581790
Coldresidential4.02.02822,493
Mixedcommercial––738381
Mixedresidential3.53.0444871
Hotcommercial––1,64887
Hotresidential4.54.01,251133
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1500 W
c__t1_half_cap_power_rated
450 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
640 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5500 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1311.5900000000001 W
c__low_temp_half_cap_power_rated
411.3 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3100 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
6462 W
c__low_temp_half_cap_cooling_cap_rated
3338.7 W

New Zealand E3 registration details

Registration number
AAC7929
GEMS registration id
156480
Status
approved, available (self-reported)
Registration expires
3 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.