c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
3,453 kWh
347 cooling + 3,106 heating
Estimated running cost
$1,139 / year
$95 / month Β· $11,395 over 10 years
Capacity
6 kW cooling
7.5 kW heating

27% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 1% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 54% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,453$1,139$11,395
Mixed zone 1,649$544$5,442
Hot zone 1,699$561$5,607

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-18CHSD/VEIH5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53T*5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53TC5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/UD5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Heat pumps similar to the Hitachi

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr3.5$686
Daikin RXM60AVMA / FTXM60AVMA7.2 kW heating6 kW cooling2,420 kWh/yr5$799
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Mitsubishi Electric MUZ-AP60VGD2/MSZ-AP60VGKD26.8 kW heating6 kW cooling2,490 kWh/yr4.5$822
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr3.5$687
Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr0$723
Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD26.8 kW heating6 kW cooling2,490 kWh/yr4.5$822
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Compare PAS-2.5UFASNQ1 / PPFC-2.5UFA1NQ with another model

Hitachi specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
6.00 kW
Cooling power input
1.66 kW
Rated heating capacity (7 Β°C)
7.50 kW
Heating power input
2.02 kW
EER, full load (tested)
3.61
COP, full load (tested)
3.68
Rated AEER
3.55
Rated ACOP
3.66
Standby power (PIA)
9.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––732965
Coldresidential3.01.53473,106
Mixedcommercial––924463
Mixedresidential2.52.05421,107
Hotcommercial––2,054100
Hotresidential3.53.01,546153
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1600 W
c__t1_half_cap_power_rated
565 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
720 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5200 W
h__h1_half_cap_heat_cap_rated
3800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1517.24 W
c__low_temp_half_cap_power_rated
516.41 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
6462 W
c__low_temp_half_cap_cooling_cap_rated
3231 W

New Zealand E3 registration details

Registration number
AAC7996
GEMS registration id
158235
Status
approved, available (self-reported)
Registration expires
8 January 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9