New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Hitachi RAC-S60YHAB/RAS-S60YHAB Heat Pump
Hitachi RAC-S60YHAB/RAS-S60YHAB is a 6 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7588).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 2,643 kWh
- 296 cooling + 2,347 heating
- Estimated running cost
- $872 / year
- $73 / month Β· $8,722 over 10 years
- Capacity
- 6 kW cooling
- 7 kW heating
3% less electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 66% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hitachi RAC-S60YHAB running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,643 | $872 | $8,722 |
| Mixed zone | 1,293 | $427 | $4,267 |
| Hot zone | 1,504 | $496 | $4,963 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hyundai HYSSSAC53TC5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| TCL TAC-VX18HSV/U*5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| TCL TAC-VX18HSV/UC5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 | |
| Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr | 4 | $639 |
Heat pumps similar to the Hitachi RAC-S60YHAB
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM60AVMA / FTXM60AVMA7.2 kW heating6 kW cooling2,420 kWh/yr | 5 | $799 | |
| Toshiba RAS-22ZAVSG-A / RAS-22ZKVSG-A6.9 kW heating6 kW cooling2,602 kWh/yr | 4 | $859 | |
| Midea MFEP60VB-W/MFEP60VB-N6.6 kW heating6 kW cooling2,517 kWh/yr | 5 | $831 | |
| Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 | |
| Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling2,517 kWh/yr | 5 | $831 | |
| Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGD26.8 kW heating6 kW cooling2,490 kWh/yr | 4.5 | $822 | |
| Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr | 5 | $798 | |
| Mitsubishi Electric MUZ-AP60VG2/MSZ-AP60VGKD26.8 kW heating6 kW cooling2,490 kWh/yr | 4.5 | $822 |
Compare RAC-S60YHAB/RAS-S60YHAB with another model
Hitachi RAC-S60YHAB specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 6.00 kW
- Cooling power input
- 1.58 kW
- Rated heating capacity (7 Β°C)
- 7.00 kW
- Heating power input
- 1.73 kW
- EER, full load (tested)
- 4.05
- COP, full load (tested)
- 4.00
- Rated AEER
- 3.77
- Rated ACOP
- 4.02
- Standby power (PIA)
- 3.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 60 dB(A)
- Outdoor sound power
- 63 dB(A)
- Demand response (AS/NZS 4755)
- Yes (requires additional part)
- Dimensions (WΓHΓD)
- 1100 Γ 300 Γ 260 mm
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hitachi RAC-S60YHAB zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 640 | 717 |
| Coldresidential | residential | 4.0 | 2.0 | 296 | 2,347 |
| Mixedcommercial | commercial | β | β | 816 | 355 |
| Mixedresidential | residential | 3.5 | 3.0 | 473 | 820 |
| Hotcommercial | commercial | β | β | 1,848 | 73 |
| Hotresidential | residential | 4.0 | 4.0 | 1,390 | 114 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 2000 W
- c__t1_half_cap_power_rated
- 500 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 580 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 5800 W
- h__h1_half_cap_heat_cap_rated
- 3500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 1444.1200000000001 W
- c__low_temp_half_cap_power_rated
- 457 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 6462 W
- c__low_temp_half_cap_cooling_cap_rated
- 3231 W
New Zealand E3 registration details
- Registration number
- AAC7588
- GEMS registration id
- 154762
- Status
- approved, available (self-reported)
- Registration expires
- 26 June 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.