c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,234 kWh
382 cooling + 2,852 heating
Estimated running cost
$1,067 / year
$89 / month Β· $10,672 over 10 years
Capacity
7 kW cooling
8 kW heating

3% more electricity than the median of 199 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 43% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 58% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi RAC-S70YHAB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,234$1,067$10,672
Mixed zone 1,584$523$5,227
Hot zone 1,921$634$6,339

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the Hitachi RAC-S70YHAB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRF070N8/42QRF070N87.5 kW heating7 kW cooling2,949 kWh/yr4$973
Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling2,949 kWh/yr4$973
Kaden KSI247.5 kW heating7 kW cooling2,932 kWh/yr4$968
Rinnai HSNRTX707.5 kW heating7 kW cooling2,949 kWh/yr4$973
Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling2,929 kWh/yr4$967
Midea MFAG70VB-W/MFAG70VB-N7.5 kW heating7 kW cooling2,949 kWh/yr4$973
Carrier 42QHG070N8PB/38QUH070N8PB7.5 kW heating7 kW cooling2,949 kWh/yr4$973
Kaden KSI-7.07.5 kW heating7 kW cooling2,949 kWh/yr4$973

Compare RAC-S70YHAB/RAS-S70YHAB with another model

Hitachi RAC-S70YHAB specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
–
EER, full load (tested)
3.57
COP, full load (tested)
4.06
Rated AEER
3.52
Rated ACOP
4.02
Standby power (PIA)
3.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61 dB(A)
Outdoor sound power
64 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-S70YHAB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––837882
Coldresidential3.52.03822,852
Mixedcommercial––1,064415
Mixedresidential3.02.5608976
Hotcommercial––2,39383
Hotresidential3.53.51,790131
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1850 W
c__t1_half_cap_power_rated
690 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
670 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5800 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1809.72 W
c__low_temp_half_cap_power_rated
630.66 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3650 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7539 W
c__low_temp_half_cap_cooling_cap_rated
3931.05 W

New Zealand E3 registration details

Registration number
AAC7592
GEMS registration id
–
Status
approved
Registration expires
26 June 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. Manufacturer: hitachiaircon.com/au. How the derived figures are calculated.