New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Hyundai HYSSSAC72TD Heat Pump
Hyundai HYSSSAC72TD is a 7.2 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8922).
- Energy rating (cooling)
- 3.5
- Heating: 2
- Annual electricity use
- 2,833 kWh
- 393 cooling + 2,440 heating
- Estimated running cost
- $935 / year
- $78 / month Β· $9,349 over 10 years
- Capacity
- 7.2 kW cooling
- 7.3 kW heating
10% less electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 92% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 64% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hyundai HYSSSAC72TD running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,833 | $935 | $9,349 |
| Mixed zone | 1,518 | $501 | $5,009 |
| Hot zone | 1,968 | $649 | $6,494 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr | 3 | $853 | |
| Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr | 3 | $860 | |
| Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr | 5 | $862 | |
| Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr | 0.5 | $883 | |
| Solar Acdc DGWA1-ACDC-24KR27 kW heating6.4 kW cooling2,743 kWh/yr | 3 | $905 |
Heat pumps similar to the Hyundai HYSSSAC72TD
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar TCHV07T1S/TSHV07T1S7.3 kW heating7.2 kW cooling2,833 kWh/yr | 3.5 | $935 | |
| Braemar TCHV70T1S/TSHV70T1S7.2 kW heating7.2 kW cooling2,905 kWh/yr | 3.5 | $959 | |
| Ers Tech ERS-AC72F017.2 kW heating7.2 kW cooling2,905 kWh/yr | 3.5 | $959 | |
| Bonaire CRC6911071/CRC69111717.2 kW heating7.2 kW cooling2,905 kWh/yr | 3.5 | $959 | |
| TCL TAC-VX24HSV/UB7.3 kW heating7.2 kW cooling2,833 kWh/yr | 3.5 | $935 | |
| Bonaire STH072S1AE/STH072S1AI7.3 kW heating7.2 kW cooling2,833 kWh/yr | 3.5 | $935 | |
| Hisense HAWG24KR7.5 kW heating7.2 kW cooling2,940 kWh/yr | 4 | $970 | |
| TCL TAC-VX24HSV/U*7.3 kW heating7.2 kW cooling2,833 kWh/yr | 3.5 | $935 |
Compare HYSSSAC72TD with another model
Hyundai HYSSSAC72TD specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.20 kW
- Cooling power input
- 2.09 kW
- Rated heating capacity (7 Β°C)
- 7.30 kW
- Heating power input
- 1.83 kW
- EER, full load (tested)
- 3.35
- COP, full load (tested)
- 4.04
- Rated AEER
- 3.42
- Rated ACOP
- 3.96
- Standby power (PIA)
- 4.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 63.8 dB(A)
- Outdoor sound power
- 65.9 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hyundai HYSSSAC72TD zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 791 | 768 |
| Coldresidential | residential | 3.5 | 2.0 | 393 | 2,440 |
| Mixedcommercial | commercial | β | β | 1,038 | 394 |
| Mixedresidential | residential | 3.0 | 3.0 | 625 | 893 |
| Hotcommercial | commercial | β | β | 2,406 | 84 |
| Hotresidential | residential | 3.5 | 3.5 | 1,836 | 132 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 2030 W
- c__t1_half_cap_power_rated
- 695 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 660 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 6400 W
- h__h1_half_cap_heat_cap_rated
- 3680 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 560 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3760 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 3590 W
Other model numbers on registration AAC8922
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8922
- GEMS registration id
- 169773
- Status
- approved, available (self-reported)
- Registration expires
- 27 May 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- HYSSSAC72T*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.