c/kWh
Energy rating (cooling)
1.5
Annual electricity use
146 kWh
Estimated running cost
$48 / year
$4 / month Β· $482 over 10 years
Capacity
1.8 kW cooling

3% more electricity than the median of 19 comparable 2 kW cooling only window / wall registrations (142 kWh a year) in the cold zone. Uses less than 26% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 99% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hyundai HYVWDAC17TA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 146$48$482
Mixed zone 223$74$736
Hot zone 651$215$2,148

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 1.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Gree GJC05AI-K6NMNB3A1.6 kW cooling130 kWh/yr1.5$43
Westinghouse WWH16CWA1.6 kW cooling130 kWh/yr1.5$43
TECO TWW16CFDG1.6 kW cooling130 kWh/yr1.5$43
Kelvinator KWH16CMF1.6 kW cooling130 kWh/yr1.5$43
Gree GJC05AI-K6NMNR1A1.6 kW cooling130 kWh/yr1.5$43

Heat pumps similar to the Hyundai HYVWDAC17TA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KAWDACC17TC1.7 kW cooling142 kWh/yr1.5$47
Kogan KAWDACC17TA1.7 kW cooling142 kWh/yr1.5$47
Bonaire CRC60000171.7 kW cooling142 kWh/yr1.5$47
Heller HWA171.7 kW cooling142 kWh/yr1.5$47
Dimplex DCB05C1.7 kW cooling142 kWh/yr1.5$47
Euromatic EUR-5000WAC11.7 kW cooling142 kWh/yr1.5$47

Other Hyundai models of similar capacity

ModelStarsEst. cost / yrCompare
Hyundai HYWINAC17TA1.7 kW cooling142 kWh/yr1.5$47
Hyundai HYWINAC17TB1.7 kW cooling142 kWh/yr1.5$47

Compare HYVWDAC17TA with another model

Hyundai HYVWDAC17TA specifications

Type
Cooling only
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
1.75 kW
Cooling power input
0.55 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.15
COP, full load (tested)
–
Rated AEER
3.16
Rated ACOP
–
Standby power (PIA)
1.0 W
Compressor
Fixed speed
Refrigerant
R290
Power supply
Single phase
Indoor sound power
60 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hyundai HYVWDAC17TA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––316–
Coldresidential1.5–146–
Mixedcommercial––401–
Mixedresidential1.5–223–
Hotcommercial––879–
Hotresidential2.0–651–
Part-load test points (3 values)
c__low_temp_full_cap_power_rated
460 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
1800 W

Other model numbers on registration AAC8838

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8838
GEMS registration id
169315
Status
approved, available (self-reported)
Registration expires
9 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
HYVWDAC17T*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.