c/kWh
Energy rating (cooling)
4.5
Heating: 3
Annual electricity use
8,311 kWh
941 cooling + 7,370 heating
Estimated running cost
$2,743 / year
$229 / month Β· $27,426 over 10 years
Capacity
21.5 kW cooling
26.1 kW heating

7% less electricity than the median of 18 comparable 20 kW reverse cycle ducted multi-split / vrf registrations (8,936 kWh a year) in the cold zone. Uses less than 72% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 17% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

iCongo AU-V215W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,311$2,743$27,426
Mixed zone 4,147$1,369$13,685
Hot zone 4,575$1,510$15,098

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 21.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-8ME2R825 kW heating22.4 kW cooling6,860 kWh/yr3$2,264
Panasonic U-8ME2R8E25 kW heating22.4 kW cooling6,860 kWh/yr3$2,264
iCongo AU-V190W/N4-G0123.3 kW heating19 kW cooling7,561 kWh/yr4$2,495

Heat pumps similar to the iCongo AU-V215W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Gree GMV-224WM/C-X(A) / GMV-NDR22P/X1-T22.4 kW heating22.4 kW cooling8,151 kWh/yr2.5$2,690
Braemar MCHX224D313B22.4 kW heating22.4 kW cooling8,151 kWh/yr2.5$2,690
Panasonic U-8ME2R8E25 kW heating22.4 kW cooling6,860 kWh/yr3$2,264
Panasonic U-8ME2R825 kW heating22.4 kW cooling6,860 kWh/yr3$2,264
Haier AV08IMAURA25 kW heating22.4 kW cooling12,201 kWh/yr2$4,026
Braemar MCRX224D313B22.4 kW heating22.4 kW cooling9,333 kWh/yr2$3,080
Mitsubishi Heavy Industries FDC224KXZRE222.4 kW heating22.4 kW cooling10,745 kWh/yr2$3,546
Samsung Electronics AM080FXMDGH/EU25 kW heating22.4 kW cooling11,192 kWh/yr1.5$3,693

Compare AU-V215W/N4-G01 with another model

iCongo AU-V215W specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
21.50 kW
Cooling power input
4.25 kW
Rated heating capacity (7 Β°C)
26.15 kW
Heating power input
5.25 kW
EER, full load (tested)
4.90
COP, full load (tested)
4.57
Rated AEER
4.96
Rated ACOP
4.90
Standby power (PIA)
24.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
72.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

iCongo AU-V215W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,0092,311
Coldresidential4.53.09417,370
Mixedcommercial––2,5191,189
Mixedresidential4.03.51,4572,690
Hotcommercial––5,556270
Hotresidential5.04.54,161414
Part-load test points (22 values)
h__h1_min_cap_power_rated
1225 W
h__h2_ext_cap_power_rated
7260 W
c__t1_half_cap_power_rated
1580 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2080 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
7860 W
h__h2_ext_cap_heat_cap_rated
24500 W
h__h1_half_cap_heat_cap_rated
13150 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
3884.5 W
c__low_temp_half_cap_power_rated
1444.1200000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
10800 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
23155.5 W
c__low_temp_half_cap_cooling_cap_rated
11631.6 W

New Zealand E3 registration details

Registration number
AAC8004
GEMS registration id
158997
Status
approved, available (self-reported)
Registration expires
15 January 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: ecomatters.com.au. How the derived figures are calculated.