New Zealand Β· costs in NZD
Reverse cycle split system air conditioner
Kaden KDI60 / KDI60 Heat Pump
Kaden KDI60 / KDI60 is a 17 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7194).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 7,317 kWh
- 832 cooling + 6,485 heating
- Estimated running cost
- $2,415 / year
- $201 / month Β· $24,146 over 10 years
- Capacity
- 17 kW cooling
- 18 kW heating
13% less electricity than the median of 51 comparable 18 kW reverse cycle ducted split system registrations (8,396 kWh a year) in the cold zone. Uses less than 75% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 23% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kaden KDI60 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,317 | $2,415 | $24,146 |
| Mixed zone | 3,663 | $1,209 | $12,088 |
| Hot zone | 3,953 | $1,304 | $13,045 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 17 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr | 2 | $1,483 | |
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr | 3.5 | $2,279 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr | 4 | $2,332 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr | 4 | $2,332 |
Heat pumps similar to the Kaden KDI60
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai DONSR18B1TA/DINLR18B1SA18 kW heating17 kW cooling7,212 kWh/yr | 3.5 | $2,380 | |
| Rinnai DSNSR18B1TA18 kW heating17 kW cooling7,212 kWh/yr | 3.5 | $2,380 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr | 4 | $2,332 | |
| Carrier 38QSV170N8/42QSV170N8S18 kW heating17 kW cooling7,212 kWh/yr | 3.5 | $2,380 | |
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr | 3.5 | $2,279 | |
| Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr | 4 | $2,332 | |
| Actron Air LRC-170DS / LRE-170DS18 kW heating17 kW cooling7,212 kWh/yr | 3.5 | $2,380 | |
| Actron Air CRV17BT / EVV17BS17.2 kW heating17 kW cooling7,384 kWh/yr | 3 | $2,437 |
Compare KDI60 / KDI60 with another model
Kaden KDI60 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 17.00 kW
- Cooling power input
- 5.25 kW
- Rated heating capacity (7 Β°C)
- 18.00 kW
- Heating power input
- 4.55 kW
- EER, full load (tested)
- 3.27
- COP, full load (tested)
- 3.92
- Rated AEER
- 3.21
- Rated ACOP
- 3.92
- Standby power (PIA)
- 13.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 72 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kaden KDI60 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | -634 | 1,969 |
| Coldresidential | residential | 4.0 | 2.0 | 832 | 6,485 |
| Mixedcommercial | commercial | β | β | 1,130 | 987 |
| Mixedresidential | residential | 3.5 | 2.5 | 1,346 | 2,317 |
| Hotcommercial | commercial | β | β | 2,357 | 210 |
| Hotresidential | residential | 4.5 | 3.5 | 3,623 | 330 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 1100 W
- h__h1_min_cap_power_rated
- 780 W
- h__h2_ext_cap_power_rated
- 4950 W
- c__t1_half_cap_power_rated
- 2720 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1720 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 4130 W
- h__h2_ext_cap_heat_cap_rated
- 14510 W
- h__h1_half_cap_heat_cap_rated
- 8670 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 645 W
- c__t1_min_cap_cooling_cap_rated
- 4490 W
- c__low_temp_full_cap_power_rated
- 4798.5 W
- c__low_temp_half_cap_power_rated
- 1355 W
- c__t1_half_cap_cooling_cap_rated
- 8030 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 4050 W
- c__low_temp_full_cap_cooling_cap_rated
- 18309 W
- c__low_temp_half_cap_cooling_cap_rated
- 8125 W
New Zealand E3 registration details
- Registration number
- AAC7194
- GEMS registration id
- 151490
- Status
- approved, available (self-reported)
- Registration expires
- 4 December 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.