c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
3,307 kWh
382 cooling + 2,925 heating
Estimated running cost
$1,091 / year
$91 / month Β· $10,913 over 10 years
Capacity
8.5 kW cooling
8.7 kW heating

About the same electricity as the median of 22 comparable 8 kW reverse cycle fixed registrations (3,319 kWh a year) in the cold zone. Uses less than 50% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 57% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KM28 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,307$1,091$10,913
Mixed zone 1,719$567$5,673
Hot zone 1,785$589$5,891

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr4$866
Actron Air MRC-075DS-37.4 kW heating7.5 kW cooling2,654 kWh/yr4$876
Mitsubishi Electric MXZ-4F80VGD8.8 kW heating8 kW cooling2,992 kWh/yr4$987
Carrier 38QUM080D8S48.3 kW heating8.1 kW cooling3,070 kWh/yr4$1,013
Bonaire H4M080S1AE8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021

Heat pumps similar to the Kaden KM28

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MULMI0487B/MFAG20N8.8 kW heating8.7 kW cooling3,550 kWh/yr3.5$1,172
TECO TSOM82HVAG48.8 kW heating8.2 kW cooling3,440 kWh/yr3.5$1,135
Carrier 38QUM080D8S48.3 kW heating8.1 kW cooling3,070 kWh/yr4$1,013
Mitsubishi Electric MXZ-4F80VGD8.8 kW heating8 kW cooling2,992 kWh/yr4$987
Bonaire H4M080S1AE8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021
Toshiba RAS-4M27B2AVG-A9 kW heating8 kW cooling3,191 kWh/yr4$1,053
Panasonic CU-4Z80VBR9.4 kW heating8 kW cooling3,331 kWh/yr4$1,099
Midea MULMI0480B8.5 kW heating8 kW cooling3,109 kWh/yr4$1,026

Compare KM28 with another model

Kaden KM28 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
8.50 kW
Cooling power input
2.34 kW
Rated heating capacity (7 Β°C)
8.70 kW
Heating power input
2.10 kW
EER, full load (tested)
3.63
COP, full load (tested)
4.14
Rated AEER
3.55
Rated ACOP
4.04
Standby power (PIA)
16.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KM28 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––434932
Coldresidential4.02.03822,925
Mixedcommercial––561494
Mixedresidential3.52.56111,108
Hotcommercial––1,290123
Hotresidential5.03.51,600185
Part-load test points (25 values)
c__t1_min_cap_power_rated
625 W
h__h1_min_cap_power_rated
480 W
h__h2_ext_cap_power_rated
2635 W
c__t1_half_cap_power_rated
975 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
870 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2525 W
h__h2_ext_cap_heat_cap_rated
8080 W
h__h1_half_cap_heat_cap_rated
4380 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
350 W
c__t1_min_cap_cooling_cap_rated
2770 W
c__low_temp_full_cap_power_rated
2138.76 W
c__low_temp_half_cap_power_rated
520 W
c__t1_half_cap_cooling_cap_rated
4200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2720 W
c__low_temp_full_cap_cooling_cap_rated
9154.5 W
c__low_temp_half_cap_cooling_cap_rated
3930 W

New Zealand E3 registration details

Registration number
AAC7032
GEMS registration id
150096
Status
approved, available (self-reported)
Registration expires
25 September 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.