c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
4,771 kWh
601 cooling + 4,170 heating
Estimated running cost
$1,574 / year
$131 / month Β· $15,744 over 10 years
Capacity
12.3 kW cooling
12.6 kW heating

18% less electricity than the median of 18 comparable 12.5 kW reverse cycle multi-split / vrf registrations (5,818 kWh a year) in the cold zone. Uses less than 83% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 41% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kinghome KWHD(42)NK6PO running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,771$1,574$15,744
Mixed zone 2,448$808$8,078
Hot zone 2,971$980$9,804

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RSUYQ4AVMA12.5 kW heating11.2 kW cooling4,422 kWh/yr2.5$1,459
Daikin RSUYQ4A2VMA12.5 kW heating11.2 kW cooling4,424 kWh/yr2.5$1,460
Toshiba MCY-MHP0404HS-A12.5 kW heating12.1 kW cooling4,445 kWh/yr3.5$1,467
Carrier 38VS004181HCSG12.5 kW heating12.1 kW cooling4,445 kWh/yr3.5$1,467

Heat pumps similar to the Kinghome KWHD(42)NK6PO

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG ARUN040GSS512.5 kW heating12.1 kW cooling7,743 kWh/yr1.5$2,555
Hisense AWV-41HJFHH214 kW heating12.1 kW cooling5,553 kWh/yr3.5$1,832
Samsung Electronics AJ125TXJ5KH/AJ025TNAPKH13.5 kW heating12.5 kW cooling5,843 kWh/yr3$1,928
Hisense AVW-41HJFHH214 kW heating12.1 kW cooling5,553 kWh/yr3.5$1,832
Fujitsu AJT040LCLBH12.1 kW heating12.1 kW cooling4,864 kWh/yr2.5$1,605
Carrier 38VS004181HCSG12.5 kW heating12.1 kW cooling4,445 kWh/yr3.5$1,467
Toshiba MCY-MHP0404HS-A12.5 kW heating12.1 kW cooling4,445 kWh/yr3.5$1,467
Fujitsu AJT040LCLCH12.1 kW heating12.1 kW cooling4,864 kWh/yr2.5$1,605

Compare KWHD(42)NK6PO with another model

Kinghome KWHD(42)NK6PO specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
Floor mounted
Rated cooling capacity (35 Β°C)
12.30 kW
Cooling power input
3.10 kW
Rated heating capacity (7 Β°C)
12.60 kW
Heating power input
3.20 kW
EER, full load (tested)
3.89
COP, full load (tested)
4.68
Rated AEER
3.92
Rated ACOP
3.89
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.6 dB(A)
Outdoor sound power
71.4 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kinghome KWHD(42)NK6PO zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,2741,291
Coldresidential3.52.06014,170
Mixedcommercial––1,619654
Mixedresidential3.53.09531,495
Hotcommercial––3,642145
Hotresidential4.03.52,748223
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3750 W
c__t1_half_cap_power_rated
980 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1050 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
11000 W
h__h1_half_cap_heat_cap_rated
6300 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6150 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10356
GEMS registration id
181252
Status
approved, available (self-reported)
Registration expires
3 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.