New Zealand Β· costs in NZD

Reverse cycle window / wall air conditioner
Kogan KASVWAC30YA Heat Pump
Kogan KASVWAC30YA is a 3.1 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8146).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 1,767 kWh
- 217 cooling + 1,550 heating
- Estimated running cost
- $583 / year
- $49 / month Β· $5,831 over 10 years
- Capacity
- 3.1 kW cooling
- 3.2 kW heating
24% less electricity than the median of 15 comparable 3.5 kW reverse cycle window / wall registrations (2,316 kWh a year) in the cold zone. Uses less than 93% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kogan KASVWAC30YA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,767 | $583 | $5,831 |
| Mixed zone | 898 | $296 | $2,963 |
| Hot zone | 1,078 | $356 | $3,557 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 3.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Kaden KW092.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| TECO TWW27HFWDG2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 |
Heat pumps similar to the Kogan KASVWAC30YA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TVS32HVWBH3.2 kW heating3.1 kW cooling1,838 kWh/yr | 2 | $607 | |
| TECO TVS32HVUVBH3.2 kW heating3.1 kW cooling1,838 kWh/yr | 2 | $607 | |
| Kelvinator KWH27HRF2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Gree GJH09AK-K6NRND6A2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Kaden KW092.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 |
Compare KASVWAC30YA with another model
Kogan KASVWAC30YA specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 3.08 kW
- Cooling power input
- 1.00 kW
- Rated heating capacity (7 Β°C)
- 3.22 kW
- Heating power input
- 0.95 kW
- EER, full load (tested)
- 3.09
- COP, full load (tested)
- 3.34
- Rated AEER
- 3.07
- Rated ACOP
- 3.38
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 59 dB(A)
- Outdoor sound power
- 65 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kogan KASVWAC30YA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 464 | 448 |
| Coldresidential | residential | 2.0 | 1.0 | 217 | 1,550 |
| Mixedcommercial | commercial | β | β | 583 | 225 |
| Mixedresidential | residential | 2.0 | 1.5 | 335 | 563 |
| Hotcommercial | commercial | β | β | 1,362 | 42 |
| Hotresidential | residential | 2.0 | 2.5 | 1,010 | 68 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 250 W
- c__t1_half_cap_power_rated
- 460 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 430 W
- h__h1_have_min_cap_results
- Yes
- h__h2_full_cap_power_rated
- 980 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1150 W
- h__h1_half_cap_heat_cap_rated
- 1680 W
- h__h2_full_cap_heat_cap_rated
- 2200 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_min_cap_power_rated
- 210 W
- c__low_temp_full_cap_power_rated
- 914 W
- c__low_temp_half_cap_power_rated
- 420.44 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 1630 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 1070 W
- c__low_temp_full_cap_cooling_cap_rated
- 3317.16 W
- c__low_temp_half_cap_cooling_cap_rated
- 1755.51 W
Other model numbers on registration AAC8146
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8146
- GEMS registration id
- 160276
- Status
- approved, available (self-reported)
- Registration expires
- 26 March 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- KASVWAC30Y*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.