New Zealand Β· costs in NZD

Reverse cycle window / wall air conditioner
Kogan KAWDACR41TC Heat Pump
Kogan KAWDACR41TC is a 4.2 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8304).
- Energy rating (cooling)
- 1.5
- Heating: 1
- Annual electricity use
- 2,214 kWh
- 336 cooling + 1,878 heating
- Estimated running cost
- $731 / year
- $61 / month Β· $7,306 over 10 years
- Capacity
- 4.2 kW cooling
- 3.6 kW heating
4% less electricity than the median of 15 comparable 3.5 kW reverse cycle window / wall registrations (2,316 kWh a year) in the cold zone. Uses less than 53% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 73% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Kogan KAWDACR41TC running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,214 | $731 | $7,306 |
| Mixed zone | 1,246 | $411 | $4,112 |
| Hot zone | 1,617 | $534 | $5,336 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps similar to the Kogan KAWDACR41TC
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Bonaire CRC60000423.6 kW heating4.2 kW cooling2,214 kWh/yr | 1.5 | $731 | |
| Dimplex DCB143.6 kW heating4.2 kW cooling2,214 kWh/yr | 1.5 | $731 | |
| Heller HWA13R3.6 kW heating4.1 kW cooling2,175 kWh/yr | 1.5 | $718 | |
| Westinghouse WWH39HWC3.5 kW heating3.9 kW cooling2,316 kWh/yr | 2 | $764 | |
| Westinghouse WWH39HWA3.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Kelvinator KWH39HRF3.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Kelvinator WH393.6 kW heating3.9 kW cooling2,324 kWh/yr | 1.5 | $767 | |
| Midea MWFF39H3.5 kW heating3.9 kW cooling2,316 kWh/yr | 2 | $764 |
Compare KAWDACR41TC with another model
Kogan KAWDACR41TC specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 4.20 kW
- Cooling power input
- 1.28 kW
- Rated heating capacity (7 Β°C)
- 3.60 kW
- Heating power input
- 1.07 kW
- EER, full load (tested)
- 3.26
- COP, full load (tested)
- 3.22
- Rated AEER
- 3.27
- Rated ACOP
- 3.35
- Standby power (PIA)
- 1.7 W
- Compressor
- Fixed speed
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 57.8 dB(A)
- Outdoor sound power
- 63.8 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Kogan KAWDACR41TC zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 740 | 614 |
| Coldresidential | residential | 1.5 | 1.0 | 336 | 1,878 |
| Mixedcommercial | commercial | β | β | 930 | 327 |
| Mixedresidential | residential | 1.5 | 1.0 | 512 | 734 |
| Hotcommercial | commercial | β | β | 2,041 | 69 |
| Hotresidential | residential | 2.0 | 1.0 | 1,506 | 111 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 970 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 2620 W
- c__low_temp_full_cap_power_rated
- 1140 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 4700 W
Other model numbers on registration AAC8304
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8304
- GEMS registration id
- 162481
- Status
- approved, available (self-reported)
- Registration expires
- 19 June 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- KAWDACR41T*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5