c/kWh
Energy rating (cooling)
1.5
Annual electricity use
1,467 kWh
Estimated running cost
$484 / year
$40 / month Β· $4,841 over 10 years
Capacity
17 kW cooling

Only 4 comparable registrations in this cohort, so no percentile is shown.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 81% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Lennox TSA060S41-3 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,467$484$4,841
Mixed zone 2,201$726$7,263
Hot zone 6,365$2,100$21,005

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 17 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Bonaire CRC6940017/CRC694011717 kW cooling870 kWh/yr3.5$287
Bonaire CRC6943017/CRC694011717 kW cooling890 kWh/yr3.5$294
Brivis DONSC17Z71 / DINXU17Z716.2 kW cooling897 kWh/yr3$296
Actron Air CCA170T / EAA170S16.7 kW cooling1,251 kWh/yr2$413
Braemar KCHV160D1B/KACV160D1S16 kW cooling1,290 kWh/yr1.5$426

Heat pumps similar to the Lennox TSA060S41-3

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6940017/CRC694011717 kW cooling870 kWh/yr3.5$287
Bonaire CRC6943017/CRC694011717 kW cooling890 kWh/yr3.5$294
Actron Air CCA170T / EAA170S16.7 kW cooling1,251 kWh/yr2$413
Actron Air CCA170S / EAA170S16.5 kW cooling1,300 kWh/yr2$429
Brivis DONSC17Z71 / DINXU17Z716.2 kW cooling897 kWh/yr3$296
Braemar KCHV160D1B/KACV160D1S16 kW cooling1,290 kWh/yr1.5$426

Compare TSA060S41-3/CH33-62D-2F-3 with another model

Lennox TSA060S41-3 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
17.04 kW
Cooling power input
5.07 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.26
COP, full load (tested)
–
Rated AEER
3.30
Rated ACOP
–
Standby power (PIA)
26.9 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
80 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
United States of America

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Lennox TSA060S41-3 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,308–
Coldresidential1.5–1,467–
Mixedcommercial––4,067–
Mixedresidential1.5–2,201–
Hotcommercial––8,725–
Hotresidential1.5–6,365–
Part-load test points (1 values)
c__low_temp_have_full_cap_results
No

Other model numbers on registration AAC6337

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6337
GEMS registration id
142623
Status
approved, available (self-reported)
Registration expires
10 November 2026
Registered for sale in
Australia, New Zealand
Family
TSA060S41-3
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: lennox.com. How the derived figures are calculated.