c/kWh
Energy rating (cooling)
4
Heating: 1.5
Annual electricity use
3,506 kWh
360 cooling + 3,146 heating
Estimated running cost
$1,157 / year
$96 / month Β· $11,570 over 10 years
Capacity
7.1 kW cooling
7.7 kW heating

12% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 11% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG AS24S2U running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,506$1,157$11,570
Mixed zone 1,702$562$5,617
Hot zone 1,863$615$6,148

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the LG AS24S2U

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASSSAC71HA7.5 kW heating7.1 kW cooling2,824 kWh/yr4.5$932
Mitsubishi Heavy Industries DXC24ZRA-W / DXK24ZRA-W8 kW heating7.1 kW cooling3,062 kWh/yr3.5$1,010
Haier 1U71TPHRA / AS71TPHRA7.5 kW heating7.1 kW cooling2,815 kWh/yr4$929
Braemar WCHV70D1T/WSHV70D1T7.1 kW heating7.1 kW cooling2,879 kWh/yr3.5$950
Gree GWH24AVEXH-K6DNA1D/O / GWH24AVEXH-K6DNA1D/I7.8 kW heating7.1 kW cooling3,034 kWh/yr3.5$1,001
Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr3.5$912
Gree GWH24AVEXH-K6DNA1C/O / GWH24AVEXH-K6DNA1C/I7.8 kW heating7.1 kW cooling2,992 kWh/yr4.5$987
Kogan KASSSAC71HD7.5 kW heating7.1 kW cooling2,824 kWh/yr4.5$932

Compare AS24S2U / AS24S2N with another model

LG AS24S2U specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
2.20 kW
Rated heating capacity (7 Β°C)
7.70 kW
Heating power input
2.10 kW
EER, full load (tested)
3.29
COP, full load (tested)
3.74
Rated AEER
3.22
Rated ACOP
3.66
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
837 Γ— 308 Γ— 189 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG AS24S2U zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––537982
Coldresidential4.01.53603,146
Mixedcommercial––805496
Mixedresidential3.52.05791,123
Hotcommercial––2,01699
Hotresidential3.52.51,706157
Part-load test points (21 values)
c__t1_min_cap_power_rated
420 W
h__h2_ext_cap_power_rated
2630 W
c__t1_half_cap_power_rated
900 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
845 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6230 W
h__h1_half_cap_heat_cap_rated
3850 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
310 W
c__t1_min_cap_cooling_cap_rated
1750 W
c__low_temp_half_cap_power_rated
600 W
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2275 W
c__low_temp_half_cap_cooling_cap_rated
3650 W

New Zealand E3 registration details

Registration number
AAC9444
GEMS registration id
172385
Status
approved, available (self-reported)
Registration expires
17 September 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.