New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, cassette
LG UU100WR3 U30/UTN100MA NA0 Heat Pump
LG UU100WR3 U30/UTN100MA NA0 is a 9.5 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8133).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 4,473 kWh
- 547 cooling + 3,926 heating
- Estimated running cost
- $1,476 / year
- $123 / month Β· $14,761 over 10 years
- Capacity
- 9.5 kW cooling
- 10.8 kW heating
1% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 47% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 43% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
LG UU100WR3 U30 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,473 | $1,476 | $14,761 |
| Mixed zone | 2,242 | $740 | $7,399 |
| Hot zone | 2,602 | $859 | $8,587 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Fujitsu AOTH30KNTA/ASTH30KNTA9 kW heating8.5 kW cooling3,477 kWh/yr | 4 | $1,147 | |
| Fujitsu AOTH30KMTD/ASTH30KMTD9 kW heating8.5 kW cooling3,477 kWh/yr | 4 | $1,147 |
Heat pumps similar to the LG UU100WR3 U30
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTH34KMTD/ASTH34KMTD10.3 kW heating9.5 kW cooling4,345 kWh/yr | 4 | $1,434 | |
| Panasonic U-100PZH3R5/S-100PK3R9.5 kW heating9.5 kW cooling3,588 kWh/yr | 3 | $1,184 | |
| Fujitsu AOTH34KNTA/ASTH34KNTA10.3 kW heating9.5 kW cooling4,345 kWh/yr | 4 | $1,434 | |
| Mitsubishi Heavy Industries SRC95ZRA-W / SRK95ZRA-W10.3 kW heating9.5 kW cooling3,948 kWh/yr | 3.5 | $1,303 | |
| Panasonic U-100PZH3R8/S-100PK3R9.5 kW heating9.5 kW cooling3,588 kWh/yr | 3 | $1,184 | |
| Daikin RXM95WVMA / FTXM95WVMA10.3 kW heating9.5 kW cooling4,691 kWh/yr | 3 | $1,548 | |
| Mitsubishi Heavy Industries DXC33ZRA-W /DXK33ZRA-W10.3 kW heating9.5 kW cooling3,948 kWh/yr | 3.5 | $1,303 |
Other LG models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG UU100WR2 U30/UTN100MA NA010.8 kW heating9.5 kW cooling5,424 kWh/yr | 2 | $1,790 |
Compare UU100WR3 U30/UTN100MA NA0 with another model
LG UU100WR3 U30 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 9.50 kW
- Cooling power input
- 2.26 kW
- Rated heating capacity (7 Β°C)
- 10.80 kW
- Heating power input
- 2.43 kW
- EER, full load (tested)
- 4.44
- COP, full load (tested)
- 4.47
- Rated AEER
- 4.11
- Rated ACOP
- 4.35
- Standby power (PIA)
- 15.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China, South Korea
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
LG UU100WR3 U30 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,181 | 1,269 |
| Coldresidential | residential | 3.0 | 2.0 | 547 | 3,926 |
| Mixedcommercial | commercial | β | β | 1,470 | 629 |
| Mixedresidential | residential | 3.0 | 2.5 | 836 | 1,406 |
| Hotcommercial | commercial | β | β | 3,196 | 147 |
| Hotresidential | residential | 3.5 | 3.0 | 2,379 | 223 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 2540 W
- c__t1_half_cap_power_rated
- 950 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1020 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 8120 W
- h__h1_half_cap_heat_cap_rated
- 5400 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 2065.64 W
- c__low_temp_half_cap_power_rated
- 868.3000000000001 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4800 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 10231.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 5169.599999999999 W
New Zealand E3 registration details
- Registration number
- AAC8133
- GEMS registration id
- 160213
- Status
- approved, available (self-reported)
- Registration expires
- 24 March 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.