c/kWh
Energy rating (cooling)
4
Heating: 1.5
Annual electricity use
3,684 kWh
342 cooling + 3,342 heating
Estimated running cost
$1,216 / year
$101 / month Β· $12,157 over 10 years
Capacity
7.1 kW cooling
7.7 kW heating

17% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 3% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG WS24SLU-23 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,684$1,216$12,157
Mixed zone 1,703$562$5,620
Hot zone 1,800$594$5,940

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the LG WS24SLU-23

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Gree GWH24AVEXH-K6DNA1D/O / GWH24AVEXH-K6DNA1D/I7.8 kW heating7.1 kW cooling3,034 kWh/yr3.5$1,001
Kogan KASSSAC71H*7.5 kW heating7.1 kW cooling2,824 kWh/yr4.5$932
Mitsubishi Heavy Industries SRK/DXK_71/24ZRA-W8 kW heating7.1 kW cooling3,062 kWh/yr3.5$1,010
Braemar WCHV70D1T/WSHV70D1T7.1 kW heating7.1 kW cooling2,879 kWh/yr3.5$950
Kogan KASSSAC71HB7.5 kW heating7.1 kW cooling2,824 kWh/yr4.5$932
Haier 1U71TPHRA / AS71TPHRA7.5 kW heating7.1 kW cooling2,815 kWh/yr4$929
Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr3.5$912
Gree GWH24AVEXH-K6DNA1C/O / GWH24AVEXH-K6DNA1C/I7.8 kW heating7.1 kW cooling2,992 kWh/yr4.5$987

Compare WS24SLU-23 / WS24SLN-23 with another model

LG WS24SLU-23 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
2.15 kW
Rated heating capacity (7 Β°C)
7.70 kW
Heating power input
2.10 kW
EER, full load (tested)
3.38
COP, full load (tested)
3.84
Rated AEER
3.30
Rated ACOP
3.66
Standby power (PIA)
0.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65.3 dB(A)
Outdoor sound power
63.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG WS24SLU-23 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,2381,012
Coldresidential4.01.53423,342
Mixedcommercial––408470
Mixedresidential4.02.05421,161
Hotcommercial––2,82686
Hotresidential4.03.01,663137
Part-load test points (23 values)
c__t1_min_cap_power_rated
500 W
h__h2_ext_cap_power_rated
1800 W
c__t1_half_cap_power_rated
710 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
740 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5200 W
h__h1_half_cap_heat_cap_rated
3850 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
265 W
c__t1_min_cap_cooling_cap_rated
2600 W
c__low_temp_full_cap_power_rated
1965.1000000000001 W
c__low_temp_half_cap_power_rated
630 W
c__t1_half_cap_cooling_cap_rated
3550 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1900 W
c__low_temp_full_cap_cooling_cap_rated
7646.7 W
c__low_temp_half_cap_cooling_cap_rated
3760 W

New Zealand E3 registration details

Registration number
AAC7755
GEMS registration id
156387
Status
approved, available (self-reported)
Registration expires
2 September 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.