Reverse cycle split system air conditioner, cassette
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W Heat Pump
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W is a 7.2 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8041).
- Energy rating (cooling)
- 4
- Heating: 2.5
- Annual electricity use
- 2,745 kWh
- 331 cooling + 2,414 heating
- Estimated running cost
- $906 / year
- $75 / month Β· $9,059 over 10 years
- Capacity
- 7.2 kW cooling
- 7.7 kW heating
13% less electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 96% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mdv running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,745 | $906 | $9,059 |
| Mixed zone | 1,404 | $463 | $4,633 |
| Hot zone | 1,589 | $524 | $5,244 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr | 3 | $853 | |
| Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr | 3 | $860 | |
| Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr | 5 | $862 |
Heat pumps similar to the Mdv
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi PAS-3.0UFASNQ1 / PCI-3.0UFA1NQ8.6 kW heating7.2 kW cooling3,499 kWh/yr | 3.5 | $1,155 | |
| Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr | 3 | $875 | |
| Fujitsu AOTH24KBTA/AUTH24KRTA8 kW heating7.1 kW cooling3,214 kWh/yr | 3 | $1,061 | |
| Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr | 3 | $879 | |
| Mitsubishi Electric PUZ-ZM71VHA-A/PLA-M71EA2-A8 kW heating7.1 kW cooling3,086 kWh/yr | 2.5 | $1,018 | |
| Mitsubishi Electric PUZ-ZM71VHA*-A/PLA-M71EA*-A Series8 kW heating7.1 kW cooling3,086 kWh/yr | 2.5 | $1,018 | |
| Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr | 0.5 | $883 | |
| Toshiba RAV-GP801ATP-A/RAV-GM801UTP-A8 kW heating7.1 kW cooling3,233 kWh/yr | 3.5 | $1,067 |
Compare C-UV-74N8-QC3W / CSV-72N8-QC7W with another model
Mdv specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 7.20 kW
- Cooling power input
- 1.83 kW
- Rated heating capacity (7 Β°C)
- 7.70 kW
- Heating power input
- 1.72 kW
- EER, full load (tested)
- 3.80
- COP, full load (tested)
- 4.34
- Rated AEER
- 3.91
- Rated ACOP
- 4.45
- Standby power (PIA)
- 3.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 57.7 dB(A)
- Outdoor sound power
- 63.7 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mdv zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 455 | 739 |
| Coldresidential | residential | 4.0 | 2.5 | 331 | 2,414 |
| Mixedcommercial | commercial | β | β | 755 | 372 |
| Mixedresidential | residential | 4.0 | 3.0 | 533 | 871 |
| Hotcommercial | commercial | β | β | 1,562 | 77 |
| Hotresidential | residential | 4.5 | 4.0 | 1,467 | 122 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 685 W
- h__h1_min_cap_power_rated
- 367 W
- h__h2_ext_cap_power_rated
- 2629 W
- c__t1_half_cap_power_rated
- 947 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 640 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2202 W
- h__h2_ext_cap_heat_cap_rated
- 7362 W
- h__h1_half_cap_heat_cap_rated
- 3583 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 500 W
- c__t1_min_cap_cooling_cap_rated
- 2755 W
- c__low_temp_full_cap_power_rated
- 1672.6200000000001 W
- c__low_temp_half_cap_power_rated
- 520 W
- c__t1_half_cap_cooling_cap_rated
- 3734 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3000 W
- c__low_temp_full_cap_cooling_cap_rated
- 7754.4 W
- c__low_temp_half_cap_cooling_cap_rated
- 3700 W
New Zealand E3 registration details
- Registration number
- AAC8041
- GEMS registration id
- 159419
- Status
- approved, available (self-reported)
- Registration expires
- 31 January 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.