c/kWh
Energy rating (cooling)
2
Heating: 0.5
Annual electricity use
39,728 kWh
4,208 cooling + 35,520 heating
Estimated running cost
$13,110 / year
$1,093 / month Β· $131,102 over 10 years
Capacity
61.5 kW cooling
61.5 kW heating

24% more electricity than the median of 25 comparable 65 kW reverse cycle multi-split / vrf registrations (32,140 kWh a year) in the cold zone. Uses less than 40% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 2% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mdv MV8-615WV2RN1E(MA) running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 39,728$13,110$131,102
Mixed zone 19,134$6,314$63,142
Hot zone 20,131$6,643$66,432

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 61.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38VT020188QTSG56 kW heating56 kW cooling2,761 kWh/yr4$911
Toshiba MMY-MUP2001HT8P-A63 kW heating56 kW cooling3,023 kWh/yr3$998
Carrier 38VT020188HTSG63 kW heating56 kW cooling3,023 kWh/yr3$998
Toshiba MMY-MAP2006FT8P-A56 kW heating56 kW cooling4,383 kWh/yr1.5$1,446
Hitachi RAS-24FSXNS77.5 kW heating67 kW cooling4,772 kWh/yr2$1,575

Heat pumps similar to the Mdv MV8-615WV2RN1E(MA)

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAS-22FSXNS69 kW heating61.5 kW cooling5,715 kWh/yr1$1,886
Carrier 38VT022188HTSG69 kW heating61.5 kW cooling3,529 kWh/yr3$1,165
Carrier 38VT022188QTSG61.5 kW heating61.5 kW cooling3,109 kWh/yr3.5$1,026
Midea MV8-615WV2RN1E(MA)61.5 kW heating61.5 kW cooling39,728 kWh/yr2$13,110
Daikin REYQ22BYM69 kW heating61.5 kW cooling47,536 kWh/yr2$15,687
Daikin REYQ22BYM969 kW heating61.5 kW cooling47,535 kWh/yr2$15,687
LG ARUM221LTE669.3 kW heating61.6 kW cooling27,109 kWh/yr3$8,946
Samsung Electronics AM220DXVGGH/SA69.3 kW heating61.6 kW cooling30,416 kWh/yr2.5$10,037

Compare MV8-615WV2RN1E(MA) with another model

Mdv MV8-615WV2RN1E(MA) specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
61.50 kW
Cooling power input
19.59 kW
Rated heating capacity (7 Β°C)
61.50 kW
Heating power input
18.20 kW
EER, full load (tested)
3.12
COP, full load (tested)
3.37
Rated AEER
3.08
Rated ACOP
3.31
Standby power (PIA)
120.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mdv MV8-615WV2RN1E(MA) zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8,87210,311
Coldresidential2.00.54,20835,520
Mixedcommercial––11,1605,254
Mixedresidential2.01.06,54312,591
Hotcommercial––24,7101,009
Hotresidential2.52.518,5861,545
Part-load test points (20 values)
h__h2_ext_cap_power_rated
16560 W
c__t1_half_cap_power_rated
6860 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
6700 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
36100 W
h__h1_half_cap_heat_cap_rated
30800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
17905.260000000002 W
c__low_temp_half_cap_power_rated
6270.04 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
30800 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
66235.5 W
c__low_temp_half_cap_cooling_cap_rated
33171.6 W

New Zealand E3 registration details

Registration number
AAC8545
GEMS registration id
165954
Status
approved, available (self-reported)
Registration expires
9 December 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.