Midea MFCA70VA-W/MFCA70VA-N is a 7 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7467).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 3,245 kWh
- 351 cooling + 2,894 heating
- Estimated running cost
- $1,071 / year
- $89 / month Β· $10,709 over 10 years
- Capacity
- 7 kW cooling
- 8.1 kW heating
3% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 40% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 58% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Midea MFCA70VA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,245 | $1,071 | $10,709 |
| Mixed zone | 1,613 | $532 | $5,323 |
| Hot zone | 1,787 | $590 | $5,897 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr | 4 | $827 | |
| Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr | 4 | $827 | |
| Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr | 3 | $853 | |
| Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr | 3 | $860 | |
| Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr | 5 | $862 |
Heat pumps similar to the Midea MFCA70VA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling2,949 kWh/yr | 4 | $973 | |
| Comfee CASG-XG70B/CASN-XG70B7.5 kW heating7 kW cooling2,949 kWh/yr | 4 | $973 | |
| Kaden KSI247.5 kW heating7 kW cooling2,932 kWh/yr | 4 | $968 | |
| Rinnai HSNRTX707.5 kW heating7 kW cooling2,949 kWh/yr | 4 | $973 | |
| Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling2,929 kWh/yr | 4 | $967 | |
| Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling2,949 kWh/yr | 4 | $973 | |
| Carrier 42QHG070N8PB/38QUH070N8PB7.5 kW heating7 kW cooling2,949 kWh/yr | 4 | $973 | |
| Kaden KSI-7.07.5 kW heating7 kW cooling2,949 kWh/yr | 4 | $973 |
Compare MFCA70VA-W/MFCA70VA-N with another model
Midea MFCA70VA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 7.00 kW
- Cooling power input
- 2.06 kW
- Rated heating capacity (7 Β°C)
- 8.05 kW
- Heating power input
- 2.25 kW
- EER, full load (tested)
- 3.56
- COP, full load (tested)
- 3.53
- Rated AEER
- 3.39
- Rated ACOP
- 3.57
- Standby power (PIA)
- 1.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 61.3 dB(A)
- Outdoor sound power
- 68.2 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea MFCA70VA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 623 | 873 |
| Coldresidential | residential | 4.0 | 2.0 | 351 | 2,894 |
| Mixedcommercial | commercial | β | β | 856 | 440 |
| Mixedresidential | residential | 3.5 | 2.5 | 567 | 1,046 |
| Hotcommercial | commercial | β | β | 2,082 | 86 |
| Hotresidential | residential | 4.0 | 3.5 | 1,649 | 138 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 610 W
- h__h1_min_cap_power_rated
- 435 W
- h__h2_ext_cap_power_rated
- 2470 W
- c__t1_half_cap_power_rated
- 785 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 760 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2320 W
- h__h2_ext_cap_heat_cap_rated
- 7030 W
- h__h1_half_cap_heat_cap_rated
- 3820 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 485 W
- c__t1_min_cap_cooling_cap_rated
- 2830 W
- c__low_temp_full_cap_power_rated
- 1882.8400000000001 W
- c__low_temp_half_cap_power_rated
- 520 W
- c__t1_half_cap_cooling_cap_rated
- 3520 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3240 W
- c__low_temp_full_cap_cooling_cap_rated
- 7539 W
- c__low_temp_half_cap_cooling_cap_rated
- 3400 W
New Zealand E3 registration details
- Registration number
- AAC7467
- GEMS registration id
- 153906
- Status
- approved, available (self-reported)
- Registration expires
- 6 May 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.