c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
3,245 kWh
351 cooling + 2,894 heating
Estimated running cost
$1,071 / year
$89 / month Β· $10,709 over 10 years
Capacity
7 kW cooling
8.1 kW heating

3% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 40% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 58% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFCA70VA-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,245$1,071$10,709
Mixed zone 1,613$532$5,323
Hot zone 1,787$590$5,897

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the Midea MFCA70VA-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling2,949 kWh/yr4$973
Comfee CASG-XG70B/CASN-XG70B7.5 kW heating7 kW cooling2,949 kWh/yr4$973
Kaden KSI247.5 kW heating7 kW cooling2,932 kWh/yr4$968
Rinnai HSNRTX707.5 kW heating7 kW cooling2,949 kWh/yr4$973
Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling2,929 kWh/yr4$967
Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling2,949 kWh/yr4$973
Carrier 42QHG070N8PB/38QUH070N8PB7.5 kW heating7 kW cooling2,949 kWh/yr4$973
Kaden KSI-7.07.5 kW heating7 kW cooling2,949 kWh/yr4$973

Compare MFCA70VA-W/MFCA70VA-N with another model

Midea MFCA70VA-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.00 kW
Cooling power input
2.06 kW
Rated heating capacity (7 Β°C)
8.05 kW
Heating power input
2.25 kW
EER, full load (tested)
3.56
COP, full load (tested)
3.53
Rated AEER
3.39
Rated ACOP
3.57
Standby power (PIA)
1.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61.3 dB(A)
Outdoor sound power
68.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFCA70VA-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––623873
Coldresidential4.02.03512,894
Mixedcommercial––856440
Mixedresidential3.52.55671,046
Hotcommercial––2,08286
Hotresidential4.03.51,649138
Part-load test points (25 values)
c__t1_min_cap_power_rated
610 W
h__h1_min_cap_power_rated
435 W
h__h2_ext_cap_power_rated
2470 W
c__t1_half_cap_power_rated
785 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
760 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2320 W
h__h2_ext_cap_heat_cap_rated
7030 W
h__h1_half_cap_heat_cap_rated
3820 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
485 W
c__t1_min_cap_cooling_cap_rated
2830 W
c__low_temp_full_cap_power_rated
1882.8400000000001 W
c__low_temp_half_cap_power_rated
520 W
c__t1_half_cap_cooling_cap_rated
3520 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3240 W
c__low_temp_full_cap_cooling_cap_rated
7539 W
c__low_temp_half_cap_cooling_cap_rated
3400 W

New Zealand E3 registration details

Registration number
AAC7467
GEMS registration id
153906
Status
approved, available (self-reported)
Registration expires
6 May 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.