c/kWh
Energy rating (cooling)
4
Heating: 1.5
Annual electricity use
2,794 kWh
303 cooling + 2,491 heating
Estimated running cost
$922 / year
$77 / month Β· $9,220 over 10 years
Capacity
6.1 kW cooling
6.5 kW heating

2% more electricity than the median of 110 comparable 6 kW reverse cycle split system registrations (2,728 kWh a year) in the cold zone. Uses less than 34% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 64% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFEF60VA-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,794$922$9,220
Mixed zone 1,340$442$4,422
Hot zone 1,546$510$5,102

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr3.5$686
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr3.5$687
Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr0$723
Hisense HAWK50KR5.4 kW heating5.4 kW cooling2,246 kWh/yr3$741
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Heat pumps similar to the Midea MFEF60VA-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRC60ZSXA-W/SRK60ZSXA-WF6.8 kW heating6.1 kW cooling2,540 kWh/yr3.5$838
Carrier Carrier Ambi6.5 kW heating6.1 kW cooling2,794 kWh/yr4$922
Comfee CASG-XG60/CASN-XG606.4 kW heating6.1 kW cooling2,645 kWh/yr4.5$873
Mitsubishi Heavy Industries SRC60ZSXA-W / SRK60ZSXA-W6.8 kW heating6.1 kW cooling2,537 kWh/yr3.5$837
Mitsubishi Electric MUZ-LN60VG2/MSZ-LN60VGDB6.8 kW heating6.1 kW cooling2,652 kWh/yr3$875
Mitsubishi Electric MUZ-LN60VGHZ/MSZ-LN60VGDV6.8 kW heating6.1 kW cooling2,652 kWh/yr3$875
LG WH21SLU-23 / WH21SLN-237 kW heating6.1 kW cooling2,741 kWh/yr5$905
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Compare MFEF60VA-W/MFEF60VA-N with another model

Midea MFEF60VA-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
6.10 kW
Cooling power input
1.78 kW
Rated heating capacity (7 Β°C)
6.55 kW
Heating power input
1.69 kW
EER, full load (tested)
3.40
COP, full load (tested)
3.85
Rated AEER
3.42
Rated ACOP
3.87
Standby power (PIA)
0.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.7 dB(A)
Outdoor sound power
67.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFEF60VA-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––483765
Coldresidential4.01.53032,491
Mixedcommercial––702375
Mixedresidential3.52.5485855
Hotcommercial––1,75168
Hotresidential4.03.51,437109
Part-load test points (23 values)
c__t1_min_cap_power_rated
480 W
h__h1_min_cap_power_rated
445 W
h__h2_ext_cap_power_rated
1630 W
c__t1_half_cap_power_rated
710 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
618 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2400 W
h__h2_ext_cap_heat_cap_rated
4700 W
h__h1_half_cap_heat_cap_rated
3280 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
355 W
c__t1_min_cap_cooling_cap_rated
1900 W
c__low_temp_half_cap_power_rated
510 W
c__t1_half_cap_cooling_cap_rated
3050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2430 W
c__low_temp_half_cap_cooling_cap_rated
3200 W

New Zealand E3 registration details

Registration number
AAC8958
GEMS registration id
169574
Status
approved, available (self-reported)
Registration expires
3 June 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.