c/kWh
Energy rating (cooling)
3.5
Annual electricity use
207 kWh
Estimated running cost
$68 / year
$6 / month Β· $683 over 10 years
Capacity
4.2 kW cooling

20% more electricity than the median of 20 comparable 3.5 kW cooling only split system registrations (173 kWh a year) in the cold zone. Uses less than 5% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 98% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Electric MUY-GW42VFD2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 207$68$683
Mixed zone 330$109$1,089
Hot zone 934$308$3,082

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Mitsubishi Electric MUY-GW42VFD2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RKM46QVMA / FTKM46QVMA4.6 kW cooling226 kWh/yr4$75
Daikin RKM46Q2VMA / FTKM46Q2VMA4.6 kW cooling228 kWh/yr4$75

Other Mitsubishi Electric models of similar capacity

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MUY-GW42VFD/MSY-GW42VFD4.2 kW cooling232 kWh/yr3$77

Compare MUY-GW42VFD2/MSY-GW42VFD2 with another model

Mitsubishi Electric MUY-GW42VFD2 specifications

Type
Cooling only
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
4.20 kW
Cooling power input
1.18 kW
Rated heating capacity (7 Β°C)
–
Heating power input
–
EER, full load (tested)
3.57
COP, full load (tested)
–
Rated AEER
3.51
Rated ACOP
–
Standby power (PIA)
5.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
59.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Electric MUY-GW42VFD2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––371–
Coldresidential3.5–207–
Mixedcommercial––504–
Mixedresidential3.5–330–
Hotcommercial––1,147–
Hotresidential4.0–934–
Part-load test points (9 values)
c__t1_half_cap_power_rated
420 W
c__t1_have_min_cap_results
No
c__low_temp_min_cap_power_rated
135 W
c__low_temp_half_cap_power_rated
295 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
2100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1160 W
c__low_temp_half_cap_cooling_cap_rated
2140 W

Other model numbers on registration AAC9098

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC9098
GEMS registration id
171249
Status
approved, available (self-reported)
Registration expires
20 July 2030
Registered for sale in
Australia, New Zealand
Family
MUY-GW42VFD2/MSY-GW42VFD2 Series
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.