New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, under ceiling
Mitsubishi Electric PUZ-M100VKA-A/PCA-M100KA3 Heat Pump
Mitsubishi Electric PUZ-M100VKA-A/PCA-M100KA3 is a 10 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9178).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 4,795 kWh
- 573 cooling + 4,222 heating
- Estimated running cost
- $1,582 / year
- $132 / month Β· $15,824 over 10 years
- Capacity
- 10 kW cooling
- 11.2 kW heating
8% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 28% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 40% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mitsubishi Electric PUZ-M100VKA-A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,795 | $1,582 | $15,824 |
| Mixed zone | 2,393 | $790 | $7,897 |
| Hot zone | 2,724 | $899 | $8,989 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Kogan KASSSAC90HD9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90HB9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 |
Heat pumps similar to the Mitsubishi Electric PUZ-M100VKA-A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Heavy Industries FDC100VSA-W / FDT100VH11.2 kW heating10 kW cooling4,192 kWh/yr | 3 | $1,383 | |
| Hitachi PAS-4.0UFASNQ1 / PPFC-4.0UFA1NQ11.5 kW heating10 kW cooling4,729 kWh/yr | 3 | $1,561 | |
| Mitsubishi Heavy Industries FDT100VH / FDC(A)100VSA-W11.2 kW heating10 kW cooling4,192 kWh/yr | 3 | $1,383 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr | 2.5 | $354 | |
| Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 | |
| Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr | 3.5 | $1,114 |
Other Mitsubishi Electric models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric PUZ-ZM100VKA-A/PCA-M100KA211.2 kW heating10 kW cooling4,446 kWh/yr | 2 | $1,467 | |
| Mitsubishi Electric PUZ-ZM100VKA-A/PCA-M100KA Series11.2 kW heating10 kW cooling4,446 kWh/yr | 2 | $1,467 |
Compare PUZ-M100VKA-A/PCA-M100KA3 with another model
Mitsubishi Electric PUZ-M100VKA-A specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Under ceiling
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.97 kW
- Rated heating capacity (7 Β°C)
- 11.20 kW
- Heating power input
- 3.38 kW
- EER, full load (tested)
- 3.41
- COP, full load (tested)
- 3.64
- Rated AEER
- 3.28
- Rated ACOP
- 3.24
- Standby power (PIA)
- 22.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Electric PUZ-M100VKA-A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 826 | 1,251 |
| Coldresidential | residential | 3.0 | 2.0 | 573 | 4,222 |
| Mixedcommercial | commercial | β | β | 1,222 | 626 |
| Mixedresidential | residential | 2.5 | 2.5 | 891 | 1,502 |
| Hotcommercial | commercial | β | β | 3,051 | 151 |
| Hotresidential | residential | 3.5 | 3.5 | 2,496 | 228 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 750 W
- h__h1_min_cap_power_rated
- 570 W
- h__h2_ext_cap_power_rated
- 3830 W
- h__h3_ext_cap_power_rated
- 3330 W
- c__t1_half_cap_power_rated
- 1050 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1080 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- Yes
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3400 W
- h__h2_ext_cap_heat_cap_rated
- 9500 W
- h__h3_ext_cap_heat_cap_rated
- 7400 W
- h__h1_half_cap_heat_cap_rated
- 5600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 500 W
- c__t1_min_cap_cooling_cap_rated
- 4000 W
- c__low_temp_half_cap_power_rated
- 790 W
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3600 W
- c__low_temp_half_cap_cooling_cap_rated
- 5000 W
Other model numbers on registration AAC9178
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC9178
- GEMS registration id
- 171653
- Status
- approved, available (self-reported)
- Registration expires
- 5 August 2030
- Registered for sale in
- Australia, New Zealand
- Family
- PUZ-M100VKA2-A/PCA-M100KA3 Series
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.