c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
4,703 kWh
769 cooling + 3,934 heating
Estimated running cost
$1,552 / year
$129 / month Β· $15,520 over 10 years
Capacity
11.2 kW cooling
11.2 kW heating

19% more electricity than the median of 20 comparable 10 kW reverse cycle registrations (3,944 kWh a year) in the cold zone. Uses less than 10% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Heavy Industries FDC112KXZEN1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,703$1,552$15,520
Mixed zone 2,719$897$8,973
Hot zone 3,439$1,135$11,349

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 11.2 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling3,675 kWh/yr3$1,213
Panasonic U-4LE2R812.5 kW heating12.1 kW cooling4,059 kWh/yr3$1,339
Panasonic U-4LE2R8E12.5 kW heating12.1 kW cooling4,059 kWh/yr3$1,339
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347
Daikin 5MXM100R2VMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431

Heat pumps similar to the Mitsubishi Heavy Industries FDC112KXZEN1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling3,675 kWh/yr3$1,213
Midea MDV-V110WN8(AUN)14 kW heating11 kW cooling4,610 kWh/yr4$1,521
Rinnai MON5H11B12.3 kW heating11.5 kW cooling4,981 kWh/yr3.5$1,644
Rinnai MON5H11B12.3 kW heating11.5 kW cooling4,981 kWh/yr3.5$1,644
Braemar NCHV10D14B11.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440
Panasonic U-4LE2R812.5 kW heating12.1 kW cooling4,059 kWh/yr3$1,339

Other Mitsubishi Heavy Industries models of similar capacity

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC112KXZEN1-W11.2 kW heating11.2 kW cooling4,775 kWh/yr2.5$1,576
Mitsubishi Heavy Industries FDCS112KXZEN1-W11.2 kW heating11.2 kW cooling4,775 kWh/yr2.5$1,576

Compare FDC112KXZEN1 with another model

Mitsubishi Heavy Industries FDC112KXZEN1 specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
11.20 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
–
EER, full load (tested)
3.69
COP, full load (tested)
4.37
Rated AEER
3.62
Rated ACOP
3.91
Standby power (PIA)
40.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDC112KXZEN1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5681,327
Coldresidential2.02.07693,934
Mixedcommercial––1,939738
Mixedresidential2.02.51,1561,563
Hotcommercial––4,156213
Hotresidential3.02.53,130309
Part-load test points (16 values)
h__h2_ext_cap_power_rated
5550 W
c__t1_half_cap_power_rated
1190 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1150 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
13000 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5600 W
c__low_temp_have_half_cap_results
No

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
FDCS112KXZEN1-WAAC102422.54,775

Other model numbers on registration AAC9712

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC9712
GEMS registration id
–
Status
approved
Registration expires
7 January 2031
Registered for sale in
Australia, New Zealand
Family
FDC(S)112KXZEN1
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 2 November 2026; last checked 3 November 2026. How the derived figures are calculated.