c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
17,147 kWh
1,962 cooling + 15,185 heating
Estimated running cost
$5,659 / year
$472 / month Β· $56,585 over 10 years
Capacity
33.5 kW cooling
37.5 kW heating

2% more electricity than the median of 20 comparable 35 kW reverse cycle multi-split / vrf registrations (16,791 kWh a year) in the cold zone. Uses less than 45% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 8% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Heavy Industries FDC335KXZE2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 17,147$5,659$56,585
Mixed zone 8,441$2,786$27,855
Hot zone 9,591$3,165$31,650

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 33.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-12MF3R737.5 kW heating33.5 kW cooling1,731 kWh/yr3.5$571
Toshiba MMY-MUP12S1HT8P-A37.5 kW heating33.5 kW cooling1,925 kWh/yr3$635
Mitsubishi Electric PUHY-M300YXM-A33.5 kW heating33.5 kW cooling2,700 kWh/yr1.5$891
Mitsubishi Electric PUHY-M300YXM series33.5 kW heating33.5 kW cooling2,700 kWh/yr1.5$891
Hitachi RAS-120RNCBLW37.5 kW heating33.5 kW cooling14,771 kWh/yr2$4,874

Heat pumps similar to the Mitsubishi Heavy Industries FDC335KXZE2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUHY-M300YXM-A-BS33.5 kW heating33.5 kW cooling2,700 kWh/yr1.5$891
Panasonic U-12MF3R737.5 kW heating33.5 kW cooling1,731 kWh/yr3.5$571
Mitsubishi Electric PUHY-M300YXM series33.5 kW heating33.5 kW cooling2,700 kWh/yr1.5$891
Hitachi RAS-120RNCBLW37.5 kW heating33.5 kW cooling14,771 kWh/yr2$4,874
Toshiba MMY-MUP12S1HT8P-A37.5 kW heating33.5 kW cooling1,925 kWh/yr3$635
Toshiba MMY-MUP1201FT8P-A33.5 kW heating33.5 kW cooling16,127 kWh/yr4$5,322
Hitachi RAS-120HNCELW37.5 kW heating33.5 kW cooling15,666 kWh/yr2.5$5,170
Daikin REYA12AYM37.5 kW heating33.5 kW cooling15,260 kWh/yr2.5$5,036

Compare FDC335KXZE2 with another model

Mitsubishi Heavy Industries FDC335KXZE2 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
33.50 kW
Cooling power input
9.40 kW
Rated heating capacity (7 Β°C)
37.50 kW
Heating power input
9.45 kW
EER, full load (tested)
3.34
COP, full load (tested)
3.85
Rated AEER
3.50
Rated ACOP
3.90
Standby power (PIA)
48.7 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDC335KXZE2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,1434,831
Coldresidential3.01.51,96215,185
Mixedcommercial––5,2282,367
Mixedresidential2.52.03,0645,377
Hotcommercial––11,664535
Hotresidential3.03.08,773818
Part-load test points (16 values)
h__h2_ext_cap_power_rated
10800 W
c__t1_half_cap_power_rated
3100 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
3810 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
27900 W
h__h1_half_cap_heat_cap_rated
18700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
16200 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10480
GEMS registration id
182042
Status
approved, available (self-reported)
Registration expires
2 November 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 26 September 2026; last checked 27 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.