c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
4,192 kWh
552 cooling + 3,640 heating
Estimated running cost
$1,383 / year
$115 / month Β· $13,834 over 10 years
Capacity
10 kW cooling
11.2 kW heating

6% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 64% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 46% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Heavy Industries FDT100VH running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,192$1,383$13,834
Mixed zone 2,213$730$7,303
Hot zone 2,722$898$8,983

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Kogan KASSSAC90HD9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HE9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210

Heat pumps similar to the Mitsubishi Heavy Industries FDT100VH

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUZ-ZM100VKA2-A/PCA-M100KA11.2 kW heating10 kW cooling4,446 kWh/yr2$1,467
Mitsubishi Electric PUZ-ZM100VKA-A/PCA-M100KA211.2 kW heating10 kW cooling4,446 kWh/yr2$1,467
Hitachi PAS-4.0UFASNQ1 / PPFC-4.0UFA1NQ11.5 kW heating10 kW cooling4,729 kWh/yr3$1,561
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr4$1,251
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354

Compare FDT100VH / FDC(A)100VSA-W with another model

Mitsubishi Heavy Industries FDT100VH specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.73 kW
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
2.54 kW
EER, full load (tested)
3.81
COP, full load (tested)
4.57
Rated AEER
3.62
Rated ACOP
4.35
Standby power (PIA)
10.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
62 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDT100VH zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1811,166
Coldresidential3.02.55523,640
Mixedcommercial––1,494605
Mixedresidential3.03.08691,344
Hotcommercial––3,343137
Hotresidential3.53.52,512210
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3150 W
c__t1_half_cap_power_rated
920 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1010 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10000 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC9789

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC9789
GEMS registration id
176603
Status
approved, available (self-reported)
Registration expires
29 January 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
FDT100VH / FDC(A)100VSA-W
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.