New Zealand Β· costs in NZD
Reverse cycle split system air conditioner, wall hung
Mitsubishi Heavy Industries SRC20ZSA-W/SRK20ZSA-WF1 Heat Pump
Mitsubishi Heavy Industries SRC20ZSA-W/SRK20ZSA-WF1 is a 2 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8239).
- Energy rating (cooling)
- 4
- Heating: 3
- Annual electricity use
- 858 kWh
- 92 cooling + 766 heating
- Estimated running cost
- $283 / year
- $24 / month Β· $2,831 over 10 years
- Capacity
- 2 kW cooling
- 2.7 kW heating
4% more electricity than the median of 63 comparable 2 kW reverse cycle split system registrations (829 kWh a year) in the cold zone. Uses less than 43% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mitsubishi Heavy Industries SRC20ZSA-W running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 858 | $283 | $2,831 |
| Mixed zone | 445 | $147 | $1,469 |
| Hot zone | 444 | $147 | $1,465 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TCL TAC-06CSHD/*IH1.8 kW heating1.8 kW cooling630 kWh/yr | 3.5 | $208 | |
| TCL TAC-06CHSD/VEIH1.8 kW heating1.8 kW cooling630 kWh/yr | 3.5 | $208 | |
| Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr | 5.5 | $234 | |
| Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr | 5.5 | $237 | |
| Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr | 5.5 | $237 |
Heat pumps similar to the Mitsubishi Heavy Industries SRC20ZSA-W
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KSI062.3 kW heating2 kW cooling718 kWh/yr | 5.5 | $237 | |
| Carrier 38QHG020N8/42QHG020N8-12.2 kW heating2 kW cooling734 kWh/yr | 5 | $242 | |
| Daikin RXV20AVMA / FTXV20AVMA2.7 kW heating2 kW cooling789 kWh/yr | 5 | $260 | |
| Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling718 kWh/yr | 5.5 | $237 | |
| Carrier 38QRG020N8/42QRG020N82.2 kW heating2 kW cooling734 kWh/yr | 5 | $242 | |
| Daikin RXM20AVMZ/FTXM20AVMZ2.8 kW heating2 kW cooling846 kWh/yr | 5 | $279 | |
| Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling708 kWh/yr | 5.5 | $234 | |
| Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling718 kWh/yr | 5.5 | $237 |
Compare SRC20ZSA-W/SRK20ZSA-WF1 with another model
Mitsubishi Heavy Industries SRC20ZSA-W specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.00 kW
- Cooling power input
- 0.41 kW
- Rated heating capacity (7 Β°C)
- 2.70 kW
- Heating power input
- 0.56 kW
- EER, full load (tested)
- 4.86
- COP, full load (tested)
- 4.88
- Rated AEER
- 4.73
- Rated ACOP
- 4.71
- Standby power (PIA)
- 3.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 49 dB(A)
- Outdoor sound power
- 56 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Heavy Industries SRC20ZSA-W zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 184 | 254 |
| Coldresidential | residential | 4.0 | 3.0 | 92 | 766 |
| Mixedcommercial | commercial | β | β | 233 | 139 |
| Mixedresidential | residential | 4.0 | 3.5 | 142 | 303 |
| Hotcommercial | commercial | β | β | 514 | 34 |
| Hotresidential | residential | 5.0 | 3.5 | 393 | 51 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 970 W
- c__t1_half_cap_power_rated
- 150 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 230 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 3200 W
- h__h1_half_cap_heat_cap_rated
- 1350 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 374.74 W
- c__low_temp_half_cap_power_rated
- 132 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 1000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 2154 W
- c__low_temp_half_cap_cooling_cap_rated
- 1075 W
Other model numbers on registration AAC8239
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC8239
- GEMS registration id
- 161010
- Status
- approved, available (self-reported)
- Registration expires
- 14 May 2029
- Registered for sale in
- Australia, New Zealand
- Family
- SRK20/DXK06ZSA-WF1
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.