c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
3,345 kWh
361 cooling + 2,984 heating
Estimated running cost
$1,104 / year
$92 / month Β· $11,039 over 10 years
Capacity
8 kW cooling
9.4 kW heating

1% more electricity than the median of 22 comparable 8 kW reverse cycle fixed registrations (3,319 kWh a year) in the cold zone. Uses less than 41% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 56% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic CU-4Z80DBR running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,345$1,104$11,039
Mixed zone 1,641$542$5,415
Hot zone 1,819$600$6,003

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr4$866
Midea MULMI0371B7.5 kW heating7.1 kW cooling2,636 kWh/yr3.5$870
Actron Air MRC-075DS-37.4 kW heating7.5 kW cooling2,654 kWh/yr4$876
Carrier 38QUM071D8S37.4 kW heating7.2 kW cooling2,692 kWh/yr3.5$888
Midea MULMI0373B/MFAG20N7.3 kW heating7.3 kW cooling2,736 kWh/yr3.5$903

Heat pumps similar to the Panasonic CU-4Z80DBR

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH30KBTA49.6 kW heating8 kW cooling3,390 kWh/yr4$1,119
Toshiba RAS-4M27U2AVG-A9 kW heating8 kW cooling3,640 kWh/yr2$1,201
Toshiba RAS-4M27B2AVG-A9 kW heating8 kW cooling3,191 kWh/yr4$1,053
Midea MULMI0480B8.5 kW heating8 kW cooling3,109 kWh/yr4$1,026
Samsung Electronics AJ080HCJ4KG9 kW heating8 kW cooling3,723 kWh/yr3$1,229
Bonaire H4M080S1AE8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021
Mitsubishi Electric MXZ-4F80VGD8.8 kW heating8 kW cooling2,992 kWh/yr4$987
Fujitsu AOTG30LBTA49.6 kW heating8 kW cooling3,685 kWh/yr2.5$1,216

Compare CU-4Z80DBR with another model

Panasonic CU-4Z80DBR specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
8.00 kW
Cooling power input
1.98 kW
Rated heating capacity (7 Β°C)
9.40 kW
Heating power input
2.03 kW
EER, full load (tested)
4.07
COP, full load (tested)
4.61
Rated AEER
4.00
Rated ACOP
4.59
Standby power (PIA)
5.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
67 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic CU-4Z80DBR zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––687917
Coldresidential4.52.53612,984
Mixedcommercial––921460
Mixedresidential4.03.05771,064
Hotcommercial––2,13197
Hotresidential4.54.01,667152
Part-load test points (20 values)
h__h1_min_cap_power_rated
500 W
h__h2_ext_cap_power_rated
2600 W
c__t1_half_cap_power_rated
680 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
845 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3000 W
h__h2_ext_cap_heat_cap_rated
8100 W
h__h1_half_cap_heat_cap_rated
4700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
555 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
4308 W

New Zealand E3 registration details

Registration number
AAC10380
GEMS registration id
180810
Status
approved, available (self-reported)
Registration expires
11 August 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.