New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Panasonic U-100PZ4R8 / S-100PE4RN Heat Pump
Panasonic U-100PZ4R8 / S-100PE4RN is a 10 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9160).
- Energy rating (cooling)
- 2.5
- Heating: 2
- Annual electricity use
- 3,866 kWh
- 564 cooling + 3,302 heating
- Estimated running cost
- $1,276 / year
- $106 / month Β· $12,758 over 10 years
- Capacity
- 10 kW cooling
- 10 kW heating
19% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 90% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-100PZ4R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,866 | $1,276 | $12,758 |
| Mixed zone | 1,449 | $478 | $4,782 |
| Hot zone | 2,203 | $727 | $7,270 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr | 4 | $1,208 | |
| Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr | 3.5 | $1,217 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr | 5 | $1,225 |
Heat pumps similar to the Panasonic U-100PZ4R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAV100CV1 / FBA100BVMA11.2 kW heating10 kW cooling4,295 kWh/yr | 3 | $1,417 | |
| Daikin RZAV100FY1 / FBA100BVMA12 kW heating10 kW cooling4,302 kWh/yr | 3.5 | $1,420 | |
| Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA Series11.2 kW heating10 kW cooling4,393 kWh/yr | 2.5 | $1,450 | |
| Pioneer International VPC-36A110 kW heating10 kW cooling4,523 kWh/yr | 3.5 | $1,493 | |
| Mitsubishi Electric PUZ-ZM100VKA2-A/PEA-M100HAA2-UF11.2 kW heating10 kW cooling4,393 kWh/yr | 2.5 | $1,450 | |
| Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr | 4.5 | $1,395 | |
| Toshiba RAV-GM1101ATP-A/RAV-GM1101DTP-A111.2 kW heating10 kW cooling4,559 kWh/yr | 2.5 | $1,504 | |
| Pioneer International VPC-36A1/CPE-36A110 kW heating10 kW cooling4,523 kWh/yr | 3.5 | $1,493 |
Compare U-100PZ4R8 / S-100PE4RN with another model
Panasonic U-100PZ4R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.90 kW
- Rated heating capacity (7 Β°C)
- 10.00 kW
- Heating power input
- 2.45 kW
- EER, full load (tested)
- 3.35
- COP, full load (tested)
- 4.02
- Rated AEER
- 3.39
- Rated ACOP
- 4.00
- Standby power (PIA)
- 15.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-100PZ4R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 115 | 3,606 |
| Coldresidential | residential | 2.5 | 2.0 | 564 | 3,302 |
| Mixedcommercial | commercial | β | β | 141 | 1,834 |
| Mixedresidential | residential | 2.5 | 2.5 | 147 | 1,302 |
| Hotcommercial | commercial | β | β | 272 | 2,505 |
| Hotresidential | residential | 2.5 | 3.0 | 349 | 1,854 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 610 W
- h__h2_ext_cap_power_rated
- 3780 W
- c__t1_half_cap_power_rated
- 1060 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1000 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3200 W
- h__h2_ext_cap_heat_cap_rated
- 10700 W
- h__h1_half_cap_heat_cap_rated
- 5000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 500 W
- c__low_temp_half_cap_power_rated
- 880 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3400 W
- c__low_temp_half_cap_cooling_cap_rated
- 5350 W
Other model numbers on registration AAC9160
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC9160
- GEMS registration id
- 171393
- Status
- approved, available (self-reported)
- Registration expires
- 31 July 2030
- Registered for sale in
- Australia, New Zealand
- Family
- U-100PZ4R8 / S-100PE4*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.