c/kWh
Energy rating (cooling)
4
Heating: 3
Annual electricity use
3,651 kWh
469 cooling + 3,182 heating
Estimated running cost
$1,205 / year
$100 / month Β· $12,048 over 10 years
Capacity
10 kW cooling
11.2 kW heating

18% less electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 91% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 51% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-100PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,651$1,205$12,048
Mixed zone 1,943$641$6,412
Hot zone 2,265$747$7,475

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R5 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114

Heat pumps similar to the Panasonic U-100PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling4,244 kWh/yr3$1,401
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Toshiba RAV-GP1101ATP-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling4,466 kWh/yr3.5$1,474
Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling4,455 kWh/yr4$1,470
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Fujitsu AOTA36LCTL/AUTA36LCLU11.2 kW heating10 kW cooling4,518 kWh/yr3$1,491
Daikin RZAV100FY1 / FCA100CVMA12 kW heating10 kW cooling3,792 kWh/yr4$1,251

Compare U-100PZH3R5/S-1014PU3E with another model

Panasonic U-100PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
–
EER, full load (tested)
4.22
COP, full load (tested)
4.76
Rated AEER
4.32
Rated ACOP
4.90
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9241,030
Coldresidential4.03.04693,182
Mixedcommercial––1,187550
Mixedresidential4.03.57281,215
Hotcommercial––2,671130
Hotresidential4.54.02,067198
Part-load test points (22 values)
h__h1_min_cap_power_rated
553 W
h__h2_ext_cap_power_rated
4310 W
c__t1_half_cap_power_rated
904 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
957 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
12500 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
449 W
c__low_temp_half_cap_power_rated
717 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3700 W
c__low_temp_half_cap_cooling_cap_rated
5300 W

New Zealand E3 registration details

Registration number
AAC9617
GEMS registration id
–
Status
approved
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.