c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
11,372 kWh
1,478 cooling + 9,894 heating
Estimated running cost
$3,753 / year
$313 / month Β· $37,528 over 10 years
Capacity
28 kW cooling
31.5 kW heating

4% less electricity than the median of 8 comparable 25 kW reverse cycle ducted multi-split / vrf registrations (11,884 kWh a year) in the cold zone. Uses less than 63% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 12% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-10ME2R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 11,372$3,753$37,528
Mixed zone 5,508$1,818$18,176
Hot zone 7,053$2,327$23,275

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 28 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Braemar MCHX280D316B28 kW heating28 kW cooling10,809 kWh/yr2.5$3,567
Gree GMV-280WM/C-X(A)28 kW heating28 kW cooling10,809 kWh/yr2.5$3,567

Heat pumps similar to the Panasonic U-10ME2R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier AV10IMAURA31.5 kW heating28 kW cooling18,587 kWh/yr2$6,134
Braemar MCHX280D316B28 kW heating28 kW cooling10,809 kWh/yr2.5$3,567
Braemar MCRX280D316B28 kW heating28 kW cooling12,333 kWh/yr1.5$4,070
Gree GMV-280WM/C-X(A)28 kW heating28 kW cooling10,809 kWh/yr2.5$3,567
Gree GMV-280WL/A-X(A)31.5 kW heating28 kW cooling14,368 kWh/yr2$4,741

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-10LE1R8E28 kW heating25 kW cooling11,434 kWh/yr2.5$3,773
Panasonic U-10LE1R828 kW heating25 kW cooling11,434 kWh/yr2.5$3,773

Compare U-10ME2R8 with another model

Panasonic U-10ME2R8 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
28.00 kW
Cooling power input
7.52 kW
Rated heating capacity (7 Β°C)
31.50 kW
Heating power input
7.14 kW
EER, full load (tested)
3.59
COP, full load (tested)
4.26
Rated AEER
3.64
Rated ACOP
4.31
Standby power (PIA)
49.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
80 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-10ME2R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,4112,826
Coldresidential3.02.51,4789,894
Mixedcommercial––3,2381,242
Mixedresidential3.03.52,2683,240
Hotcommercial––8,491293
Hotresidential3.56.56,601452
Part-load test points (21 values)
c__t1_min_cap_power_rated
1000 W
h__h1_min_cap_power_rated
710 W
h__h2_ext_cap_power_rated
6910 W
c__t1_half_cap_power_rated
2660 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
2220 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
6800 W
h__h2_ext_cap_heat_cap_rated
22800 W
h__h1_half_cap_heat_cap_rated
15750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
750 W
c__t1_min_cap_cooling_cap_rated
6700 W
c__t1_half_cap_cooling_cap_rated
14000 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
7400 W

Other model numbers on registration AAC9312

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC9312
GEMS registration id
170611
Status
approved, available (self-reported)
Registration expires
22 September 2030
Registered for sale in
Australia, New Zealand
Family
U-10ME2R8
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.