New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Panasonic U-200PE2R8A/S-200PE3R5B Heat Pump
Panasonic U-200PE2R8A/S-200PE3R5B is a 20 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8054).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 11,680 kWh
- 1,522 cooling + 10,158 heating
- Estimated running cost
- $3,854 / year
- $321 / month Β· $38,544 over 10 years
- Capacity
- 20 kW cooling
- 22.4 kW heating
6% more electricity than the median of 37 comparable 20 kW reverse cycle ducted split system registrations (11,029 kWh a year) in the cold zone. Uses less than 19% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 12% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Panasonic U-200PE2R8A running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 11,680 | $3,854 | $38,544 |
| Mixed zone | 6,197 | $2,045 | $20,450 |
| Hot zone | 7,419 | $2,448 | $24,483 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 20 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTG65LRLA/ARTG65LHTA20 kW heating18 kW cooling7,679 kWh/yr | 10 | $2,534 | |
| Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling7,978 kWh/yr | 2.5 | $2,633 | |
| Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling7,987 kWh/yr | 2.5 | $2,636 | |
| Panasonic U-180PZH3R8 / S-180PE4R20 kW heating18 kW cooling8,186 kWh/yr | 2.5 | $2,701 | |
| Panasonic U-180PZH3R5 / S-180PE4R20 kW heating18 kW cooling8,186 kWh/yr | 2.5 | $2,701 |
Heat pumps similar to the Panasonic U-200PE2R8A
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZYQ8TY1 / FDYQ200LCV122.4 kW heating20 kW cooling10,847 kWh/yr | 1.5 | $3,580 | |
| Mitsubishi Heavy Industries FDCA200VSA-W/FDUA200VH22.4 kW heating20 kW cooling9,482 kWh/yr | 3 | $3,129 | |
| Fujitsu AOTH72KRTA/ARTH72KHTA22.4 kW heating20 kW cooling9,868 kWh/yr | 2.5 | $3,256 | |
| Mitsubishi Electric PUZ-ZM200YKA-A / PEA-M200LAA22.4 kW heating20 kW cooling9,888 kWh/yr | 2.5 | $3,263 | |
| Toshiba RAV-GM2241AT8-A/RAV-RM2241DTP-E222.4 kW heating20 kW cooling10,006 kWh/yr | 2 | $3,302 | |
| Haier 1U200S5SA2FB / AD200S5SH2FA22.4 kW heating20 kW cooling9,384 kWh/yr | 2.5 | $3,097 | |
| Samsung Electronics AC200HCADNG/SA / AC200HEHPKG/SA22.5 kW heating20 kW cooling11,035 kWh/yr | 2 | $3,642 | |
| Daikin RZAS200DY1 / FDYA200AV122.4 kW heating20 kW cooling9,309 kWh/yr | 2.5 | $3,072 |
Compare U-200PE2R8A/S-200PE3R5B with another model
Panasonic U-200PE2R8A specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 20.00 kW
- Cooling power input
- 6.41 kW
- Rated heating capacity (7 Β°C)
- 22.40 kW
- Heating power input
- 6.20 kW
- EER, full load (tested)
- 3.24
- COP, full load (tested)
- 3.59
- Rated AEER
- 3.08
- Rated ACOP
- 3.56
- Standby power (PIA)
- 25.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1456 Γ 486 Γ 916 mm
- Country of manufacture
- Malaysia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-200PE2R8A zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 3,369 | 3,356 |
| Coldresidential | residential | 2.0 | 1.0 | 1,522 | 10,158 |
| Mixedcommercial | commercial | β | β | 4,199 | 1,788 |
| Mixedresidential | residential | 2.0 | 1.5 | 2,342 | 3,855 |
| Hotcommercial | commercial | β | β | 9,177 | 405 |
| Hotresidential | residential | 2.0 | 1.5 | 6,794 | 625 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 8140 W
- c__t1_half_cap_power_rated
- 2740 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 3100 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 19000 W
- h__h1_half_cap_heat_cap_rated
- 11200 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 5858.74 W
- c__low_temp_half_cap_power_rated
- 2504.36 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 10000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 21540 W
- c__low_temp_half_cap_cooling_cap_rated
- 10770 W
New Zealand E3 registration details
- Registration number
- AAC8054
- GEMS registration id
- 159444
- Status
- approved, available (self-reported)
- Registration expires
- 12 February 2029
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.