c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
5,818 kWh
880 cooling + 4,938 heating
Estimated running cost
$1,920 / year
$160 / month Β· $19,199 over 10 years
Capacity
15.5 kW cooling
16.5 kW heating

21% less electricity than the median of 24 comparable 16 kW reverse cycle multi-split / vrf registrations (7,385 kWh a year) in the cold zone. Uses less than 88% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 33% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-6LZ2E8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,818$1,920$19,199
Mixed zone 3,122$1,030$10,303
Hot zone 4,085$1,348$13,481

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 15.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RSUYA5AVM16 kW heating14 kW cooling4,941 kWh/yr3$1,631
Panasonic U-5LZ2E816 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Panasonic U-5LZ2E516 kW heating14 kW cooling5,357 kWh/yr2.5$1,768

Heat pumps similar to the Panasonic U-6LZ2E8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUMY-SM140YKM-A-BS16.5 kW heating15.5 kW cooling7,286 kWh/yr3$2,404
Mitsubishi Electric PUMY-SM140YKM-A Series16.5 kW heating15.5 kW cooling7,286 kWh/yr3$2,404
Mitsubishi Heavy Industries FDC155KXZES115.5 kW heating15.5 kW cooling7,267 kWh/yr2$2,398
Mitsubishi Heavy Industries FDC155KXZEN115.5 kW heating15.5 kW cooling7,308 kWh/yr2$2,412
Braemar MCMX160D109B18 kW heating15.5 kW cooling8,182 kWh/yr1.5$2,700
Daikin RSUYA6AVM18 kW heating16 kW cooling5,683 kWh/yr3$1,875

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-6LZ2E516.5 kW heating15.5 kW cooling5,818 kWh/yr3$1,920
Panasonic U-6LE2R816.5 kW heating15.5 kW cooling5,965 kWh/yr2.5$1,968

Compare U-6LZ2E8 with another model

Panasonic U-6LZ2E8 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
15.50 kW
Cooling power input
4.00 kW
Rated heating capacity (7 Β°C)
16.50 kW
Heating power input
3.73 kW
EER, full load (tested)
3.92
COP, full load (tested)
4.45
Rated AEER
3.77
Rated ACOP
4.29
Standby power (PIA)
34.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
71.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-6LZ2E8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,8131,531
Coldresidential3.02.58804,938
Mixedcommercial––2,276780
Mixedresidential3.03.51,3591,763
Hotcommercial––5,009203
Hotresidential3.54.53,786299
Part-load test points (18 values)
c__t1_half_cap_power_rated
1380 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1170 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
4600 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
8300 W
h__h2_full_cap_heat_cap_rated
14500 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
3656 W
c__low_temp_half_cap_power_rated
1261.32 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7800 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
16693.5 W
c__low_temp_half_cap_cooling_cap_rated
8400.6 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
U-6LZ2E8AAC1029737,817

New Zealand E3 registration details

Registration number
AAC6969
GEMS registration id
149734
Status
approved, available (self-reported)
Registration expires
8 September 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.