c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,973 kWh
335 cooling + 2,638 heating
Estimated running cost
$981 / year
$82 / month Β· $9,811 over 10 years
Capacity
6.8 kW cooling
8 kW heating

5% less electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 81% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 62% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-71PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,973$981$9,811
Mixed zone 1,497$494$4,940
Hot zone 1,613$532$5,323

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling2,078 kWh/yr3.5$686
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling2,082 kWh/yr3.5$687
Daikin RZAV60CV1 / FCTA60AVMA7.1 kW heating6 kW cooling2,191 kWh/yr0$723
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling2,417 kWh/yr5$798
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling2,417 kWh/yr5$798

Heat pumps similar to the Panasonic U-71PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Gree GVH24EBXF-K6DNA1A/O / GVH24EBXF-K6DNA1A/I8 kW heating7 kW cooling3,748 kWh/yr3$1,237
LG UU70WR2 U40/UTN70PB NB07.5 kW heating6.8 kW cooling3,980 kWh/yr1.5$1,313
Samsung Electronics AR24BXGYCWKX/ AR24BXGYCWKN7.2 kW heating6.8 kW cooling3,411 kWh/yr3$1,126
Samsung Electronics AR70H24CADWX / AR70H24CADWN7.2 kW heating6.8 kW cooling3,287 kWh/yr3.5$1,085
Daikin RXM71YFVMA / FVXM71YVMA8 kW heating6.7 kW cooling3,340 kWh/yr3$1,102
Pioneer International HPR-24A27 kW heating6.7 kW cooling2,915 kWh/yr5$962

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860

Compare U-71PZH3R5/S-6071PT3E with another model

Panasonic U-71PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
6.80 kW
Cooling power input
1.74 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
2.02 kW
EER, full load (tested)
4.35
COP, full load (tested)
4.26
Rated AEER
3.81
Rated ACOP
3.88
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1275 Γ— 235 Γ— 690 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-71PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––632805
Coldresidential3.52.53352,638
Mixedcommercial––819413
Mixedresidential3.53.0525972
Hotcommercial––1,86799
Hotresidential4.04.01,461152
Part-load test points (22 values)
h__h1_min_cap_power_rated
315 W
h__h2_ext_cap_power_rated
3080 W
c__t1_half_cap_power_rated
575 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
740 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1900 W
h__h2_ext_cap_heat_cap_rated
8000 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
255 W
c__low_temp_half_cap_power_rated
460 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2200 W
c__low_temp_half_cap_cooling_cap_rated
3550 W

New Zealand E3 registration details

Registration number
AAC9781
GEMS registration id
175923
Status
approved, available (self-reported)
Registration expires
11 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.