c/kWh
Energy rating (cooling)
5
Heating: 2
Annual electricity use
1,367 kWh
147 cooling + 1,220 heating
Estimated running cost
$451 / year
$38 / month Β· $4,511 over 10 years
Capacity
3.5 kW cooling
3.6 kW heating

2% less electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 60% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 83% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Pioneer International HPR-12A2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,367$451$4,511
Mixed zone 645$213$2,129
Hot zone 744$246$2,455

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Pioneer International HPR-12A2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399
Mitsubishi Electric MUZ-AP35VG2/MSZ-AP35VGD23.7 kW heating3.5 kW cooling1,219 kWh/yr5$402
Rinnai HONRPX35/HINRPX35M3.8 kW heating3.5 kW cooling1,217 kWh/yr6$402
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Midea MFEZ35VA-W/MFEZ35VA-N3.8 kW heating3.5 kW cooling1,217 kWh/yr6$402
Mitsubishi Electric MUZ-AP35VGD2/MSZ-AP35VGD3.7 kW heating3.5 kW cooling1,219 kWh/yr5$402
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390

Compare HPR-12A2 with another model

Pioneer International HPR-12A2 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
3.50 kW
Cooling power input
0.93 kW
Rated heating capacity (7 Β°C)
3.60 kW
Heating power input
0.88 kW
EER, full load (tested)
3.69
COP, full load (tested)
4.07
Rated AEER
3.74
Rated ACOP
4.06
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
M50
Power supply
Single phase
Indoor sound power
39 dB(A)
Outdoor sound power
53 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Pioneer International HPR-12A2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––54368
Coldresidential5.02.01471,220
Mixedcommercial––-2,046173
Mixedresidential4.53.0230415
Hotcommercial––3,27736
Hotresidential5.04.068658
Part-load test points (27 values)
c__t1_min_cap_power_rated
174 W
h__h1_min_cap_power_rated
156 W
c__t1_half_cap_power_rated
333 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
318 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1414 W
h__h2_half_cap_power_rated
383 W
h__h3_full_cap_power_rated
1434 W
h__h3_half_cap_power_rated
687 W
h__h2_have_half_cap_results
Yes
h__h3_have_full_cap_results
Yes
h__h3_have_half_cap_results
Yes
h__h1_min_cap_heat_cap_rated
944 W
h__h1_half_cap_heat_cap_rated
1768 W
h__h2_full_cap_heat_cap_rated
3080 W
h__h2_half_cap_heat_cap_rated
1540 W
h__h3_full_cap_heat_cap_rated
2988 W
h__h3_half_cap_heat_cap_rated
1472 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
87 W
c__t1_min_cap_cooling_cap_rated
598 W
c__low_temp_half_cap_power_rated
265 W
c__t1_half_cap_cooling_cap_rated
1703 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
656 W
c__low_temp_half_cap_cooling_cap_rated
1800 W

New Zealand E3 registration details

Registration number
AAC10448
GEMS registration id
182212
Status
approved, available (self-reported)
Registration expires
17 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.