c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,152 kWh
266 cooling + 1,886 heating
Estimated running cost
$710 / year
$59 / month Β· $7,102 over 10 years
Capacity
5.4 kW cooling
5.4 kW heating

About the same electricity as the median of 8 comparable 5 kW reverse cycle fixed registrations (2,155 kWh a year) in the cold zone. Uses less than 50% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 74% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai MON2H05B1LA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,152$710$7,102
Mixed zone 1,118$369$3,689
Hot zone 1,307$431$4,313

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Haier 3U55S2PR1FA5 kW heating5.2 kW cooling2,013 kWh/yr3.5$664
Rinnai MON2H05B5.3 kW heating5.2 kW cooling2,041 kWh/yr3.5$674

Heat pumps similar to the Rinnai MON2H05B1LA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAM-G55N3HCE6.8 kW heating5.5 kW cooling2,473 kWh/yr4.5$816
Haier 3U55S2PR1FA5.8 kW heating5.5 kW cooling2,455 kWh/yr2.5$810
Braemar NCHV05D12B5.6 kW heating5.3 kW cooling2,181 kWh/yr3$720
Braemar NCHV53D125.3 kW heating5.2 kW cooling2,158 kWh/yr2.5$712
Haier 3U55S2PR1FA5 kW heating5.2 kW cooling2,013 kWh/yr3.5$664
Daikin 3MXM52RVMA6.8 kW heating5.2 kW cooling2,447 kWh/yr2.5$808
Daikin 3MXM52R2VMA6.8 kW heating5.2 kW cooling2,447 kWh/yr2.5$808

Other Rinnai models of similar capacity

ModelStarsEst. cost / yrCompare
Rinnai MON2H05B5.3 kW heating5.2 kW cooling2,041 kWh/yr3.5$674

Compare MON2H05B1LA with another model

Rinnai MON2H05B1LA specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
5.40 kW
Cooling power input
1.48 kW
Rated heating capacity (7 Β°C)
5.40 kW
Heating power input
1.32 kW
EER, full load (tested)
3.72
COP, full load (tested)
4.35
Rated AEER
3.58
Rated ACOP
4.01
Standby power (PIA)
8.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
60.7 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai MON2H05B1LA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––416602
Coldresidential3.52.02661,886
Mixedcommercial––585316
Mixedresidential3.52.5418700
Hotcommercial––1,45875
Hotresidential4.03.01,194113
Part-load test points (23 values)
c__t1_min_cap_power_rated
234 W
h__h1_min_cap_power_rated
397 W
h__h2_ext_cap_power_rated
1425 W
c__t1_half_cap_power_rated
519 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
537 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2020 W
h__h2_ext_cap_heat_cap_rated
4550 W
h__h1_half_cap_heat_cap_rated
2720 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
182 W
c__t1_min_cap_cooling_cap_rated
1110 W
c__low_temp_half_cap_power_rated
376 W
c__t1_half_cap_cooling_cap_rated
2740 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1580 W
c__low_temp_half_cap_cooling_cap_rated
2670 W

New Zealand E3 registration details

Registration number
AAC9072
GEMS registration id
170781
Status
approved, available (self-reported)
Registration expires
9 July 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.