New Zealand Β· costs in NZD

Reverse cycle air conditioner
Rinnai MON3H07B1LA Heat Pump
Rinnai MON3H07B1LA is a 7.2 kW reverse cycle heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9079).
- Energy rating (cooling)
- 3.5
- Heating: 2.5
- Annual electricity use
- 2,662 kWh
- 343 cooling + 2,319 heating
- Estimated running cost
- $878 / year
- $73 / month Β· $8,785 over 10 years
- Capacity
- 7.2 kW cooling
- 7.3 kW heating
18% less electricity than the median of 9 comparable 7 kW reverse cycle registrations (3,237 kWh a year) in the cold zone. Uses less than 78% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Rinnai MON3H07B1LA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,662 | $878 | $8,785 |
| Mixed zone | 1,455 | $480 | $4,802 |
| Hot zone | 1,659 | $547 | $5,475 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps similar to the Rinnai MON3H07B1LA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar NCHV72D138.6 kW heating7.2 kW cooling3,278 kWh/yr | 2 | $1,082 | |
| Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling3,067 kWh/yr | 3 | $1,012 | |
| Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling2,634 kWh/yr | 3 | $869 | |
| Braemar NCHV07D13B8.3 kW heating7.3 kW cooling3,237 kWh/yr | 3 | $1,068 | |
| Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling3,198 kWh/yr | 4.5 | $1,055 | |
| Daikin 4MXM68R2VMA8.6 kW heating6.8 kW cooling3,649 kWh/yr | 3.5 | $1,204 | |
| Daikin 4MXM68RVMA8.6 kW heating6.8 kW cooling3,649 kWh/yr | 3.5 | $1,204 |
Other Rinnai models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai MON3H07B7.4 kW heating7.5 kW cooling2,647 kWh/yr | 3.5 | $874 |
Compare MON3H07B1LA with another model
Rinnai MON3H07B1LA specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.20 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 7.30 kW
- Heating power input
- β
- EER, full load (tested)
- 3.69
- COP, full load (tested)
- 4.53
- Rated AEER
- 3.58
- Rated ACOP
- 4.41
- Standby power (PIA)
- 12.7 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 64.5 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Rinnai MON3H07B1LA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 479 | 792 |
| Coldresidential | residential | 3.5 | 2.5 | 343 | 2,319 |
| Mixedcommercial | commercial | β | β | 722 | 441 |
| Mixedresidential | residential | 3.5 | 3.0 | 545 | 910 |
| Hotcommercial | commercial | β | β | 1,741 | 110 |
| Hotresidential | residential | 4.5 | 3.0 | 1,498 | 161 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 521 W
- h__h1_min_cap_power_rated
- 357 W
- h__h2_ext_cap_power_rated
- 2634 W
- c__t1_half_cap_power_rated
- 720 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 670 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1485 W
- h__h2_ext_cap_heat_cap_rated
- 7820 W
- h__h1_half_cap_heat_cap_rated
- 3630 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 364 W
- c__t1_min_cap_cooling_cap_rated
- 2640 W
- c__low_temp_half_cap_power_rated
- 482 W
- c__t1_half_cap_cooling_cap_rated
- 3620 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2990 W
- c__low_temp_half_cap_cooling_cap_rated
- 3720 W
New Zealand E3 registration details
- Registration number
- AAC9079
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 9 July 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 19
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.