c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
2,662 kWh
343 cooling + 2,319 heating
Estimated running cost
$878 / year
$73 / month Β· $8,785 over 10 years
Capacity
7.2 kW cooling
7.3 kW heating

18% less electricity than the median of 10 comparable 7 kW reverse cycle fixed registrations (3,247 kWh a year) in the cold zone. Uses less than 80% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai MON3H07B1LA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,662$878$8,785
Mixed zone 1,455$480$4,802
Hot zone 1,659$547$5,475

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the Rinnai MON3H07B1LA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar NCHV72D138.6 kW heating7.2 kW cooling3,278 kWh/yr2$1,082
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling2,634 kWh/yr3$869
Braemar NCHV07D13B8.3 kW heating7.3 kW cooling3,237 kWh/yr3$1,068
Haier 4U71S2PR1FA8 kW heating7.1 kW cooling3,337 kWh/yr2$1,101
Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling3,067 kWh/yr3$1,012
Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling3,198 kWh/yr4.5$1,055
Daikin 4MXM68R2VMA8.6 kW heating6.8 kW cooling3,649 kWh/yr3.5$1,204
Daikin 4MXM68RVMA8.6 kW heating6.8 kW cooling3,649 kWh/yr3.5$1,204

Compare MON3H07B1LA with another model

Rinnai MON3H07B1LA specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.20 kW
Cooling power input
1.97 kW
Rated heating capacity (7 Β°C)
7.30 kW
Heating power input
1.61 kW
EER, full load (tested)
3.69
COP, full load (tested)
4.53
Rated AEER
3.58
Rated ACOP
4.41
Standby power (PIA)
12.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
64.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai MON3H07B1LA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––479792
Coldresidential3.52.53432,319
Mixedcommercial––722441
Mixedresidential3.53.0545910
Hotcommercial––1,741110
Hotresidential4.53.01,498161
Part-load test points (23 values)
c__t1_min_cap_power_rated
521 W
h__h1_min_cap_power_rated
357 W
h__h2_ext_cap_power_rated
2634 W
c__t1_half_cap_power_rated
720 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
670 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1485 W
h__h2_ext_cap_heat_cap_rated
7820 W
h__h1_half_cap_heat_cap_rated
3630 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
364 W
c__t1_min_cap_cooling_cap_rated
2640 W
c__low_temp_half_cap_power_rated
482 W
c__t1_half_cap_cooling_cap_rated
3620 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2990 W
c__low_temp_half_cap_cooling_cap_rated
3720 W

New Zealand E3 registration details

Registration number
AAC9079
GEMS registration id
170855
Status
approved, available (self-reported)
Registration expires
9 July 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.