c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
3,274 kWh
404 cooling + 2,870 heating
Estimated running cost
$1,080 / year
$90 / month Β· $10,804 over 10 years
Capacity
7.1 kW cooling
8 kW heating

4% more electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 36% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 58% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Samsung Electronics running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,274$1,080$10,804
Mixed zone 1,588$524$5,240
Hot zone 2,007$662$6,623

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Mitsubishi Heavy Industries DXC21ZRA-W / DXK21ZRA-WF17.1 kW heating6.3 kW cooling2,507 kWh/yr4$827
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862

Heat pumps similar to the Samsung Electronics

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric PUZ-ZM71VHA2-A/PLA-M71EA-A8 kW heating7.1 kW cooling3,086 kWh/yr2.5$1,018
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Toshiba RAV-GP801ATP-A/RAV-GM801UTP-A8 kW heating7.1 kW cooling3,233 kWh/yr3.5$1,067
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Fujitsu AOTH24KBTA/AUTH24KRTA8 kW heating7.1 kW cooling3,214 kWh/yr3$1,061
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879
Mitsubishi Electric PUZ-ZM71VHA-A/PLA-M71EA2-A8 kW heating7.1 kW cooling3,086 kWh/yr2.5$1,018
Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr3$906

Compare AC071TXAPKG/SA / AC071TN4PKG/SA with another model

Samsung Electronics specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
1.92 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
2.00 kW
EER, full load (tested)
3.60
COP, full load (tested)
4.11
Rated AEER
3.69
Rated ACOP
3.99
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
China, South Korea

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Samsung Electronics zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––903804
Coldresidential3.02.04042,870
Mixedcommercial––1,139378
Mixedresidential3.03.0634954
Hotcommercial––2,55670
Hotresidential3.04.01,893114
Part-load test points (24 values)
h__h1_min_cap_power_rated
240 W
h__h2_ext_cap_power_rated
2490 W
c__t1_half_cap_power_rated
780 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
690 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1550 W
h__h2_ext_cap_heat_cap_rated
6250 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
340 W
c__low_temp_full_cap_power_rated
1754.88 W
c__low_temp_half_cap_power_rated
712.9200000000001 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3670 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
1750 W
c__low_temp_full_cap_cooling_cap_rated
7646.7 W
c__low_temp_half_cap_cooling_cap_rated
3952.5899999999997 W

New Zealand E3 registration details

Registration number
AAC8453
GEMS registration id
164376
Status
approved, available (self-reported)
Registration expires
12 September 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.