c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
3,209 kWh
382 cooling + 2,827 heating
Estimated running cost
$1,059 / year
$88 / month Β· $10,590 over 10 years
Capacity
7 kW cooling
8 kW heating

13% more electricity than the median of 17 comparable 7 kW reverse cycle fixed registrations (2,850 kWh a year) in the cold zone. Uses less than 24% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 59% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Samsung Electronics AJ070HCJ3KG running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,209$1,059$10,590
Mixed zone 1,627$537$5,369
Hot zone 1,850$611$6,105

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air MRC-075CS-37.6 kW heating7.5 kW cooling2,624 kWh/yr4$866
Midea MULMI0371B7.5 kW heating7.1 kW cooling2,636 kWh/yr3.5$870
Actron Air MRC-075DS-37.4 kW heating7.5 kW cooling2,654 kWh/yr4$876
Carrier 38QUM071D8S37.4 kW heating7.2 kW cooling2,692 kWh/yr3.5$888
Daikin 2MXF70TVMA7 kW heating7 kW cooling2,732 kWh/yr2.5$902

Heat pumps similar to the Samsung Electronics AJ070HCJ3KG

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin 2MXF70TVMA7 kW heating7 kW cooling2,732 kWh/yr2.5$902
Daikin 2MXF70T2VMA7 kW heating7 kW cooling2,732 kWh/yr2.5$902
Toshiba RAS-3M24B2AVG-A8.7 kW heating7 kW cooling3,150 kWh/yr4$1,040
Panasonic CU-4Z71VBR8.5 kW heating7.1 kW cooling3,276 kWh/yr4$1,081
Panasonic CU-4Z71DBR8.5 kW heating7.1 kW cooling3,170 kWh/yr4.5$1,046
Midea MULMI0371B7.5 kW heating7.1 kW cooling2,636 kWh/yr3.5$870
Mitsubishi Electric MXZ-4F71VGD8 kW heating7.1 kW cooling2,826 kWh/yr3.5$933
Carrier 38QUM071D8S37.4 kW heating7.2 kW cooling2,692 kWh/yr3.5$888

Compare AJ070HCJ3KG with another model

Samsung Electronics AJ070HCJ3KG specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.00 kW
Cooling power input
1.80 kW
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
1.90 kW
EER, full load (tested)
3.99
COP, full load (tested)
4.36
Rated AEER
3.80
Rated ACOP
4.12
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
62.4 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China, Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Samsung Electronics AJ070HCJ3KG zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––798902
Coldresidential3.02.03822,827
Mixedcommercial––1,005467
Mixedresidential3.02.55951,032
Hotcommercial––2,228111
Hotresidential3.53.01,681169
Part-load test points (16 values)
h__h2_ext_cap_power_rated
2500 W
c__t1_half_cap_power_rated
610 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
760 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6900 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3500 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9949
GEMS registration id
177655
Status
approved, available (self-reported)
Registration expires
17 March 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.