New Zealand Β· costs in NZD

Reverse cycle multi-split / vrf air conditioner
Samsung Electronics AM200DXVGGR/SA Heat Pump
Samsung Electronics AM200DXVGGR/SA is a 56 kW reverse cycle multi-split / vrf heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7685).
- Energy rating (cooling)
- 2.5
- Heating: 1.5
- Annual electricity use
- 27,154 kWh
- 3,477 cooling + 23,677 heating
- Estimated running cost
- $8,961 / year
- $747 / month Β· $89,608 over 10 years
- Capacity
- 56 kW cooling
- 63 kW heating
2% less electricity than the median of 55 comparable 50 kW reverse cycle multi-split / vrf registrations (27,778 kWh a year) in the cold zone. Uses less than 51% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 5% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Samsung Electronics AM200DXVGGR running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 27,154 | $8,961 | $89,608 |
| Mixed zone | 13,945 | $4,602 | $46,019 |
| Hot zone | 17,565 | $5,796 | $57,965 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 56 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Carrier 38VT018188QTSG50.4 kW heating50.4 kW cooling2,485 kWh/yr | 4 | $820 | |
| Carrier 38VT020188QTSG56 kW heating56 kW cooling2,761 kWh/yr | 4 | $911 | |
| Toshiba MMY-MUP1801HT8P-A56 kW heating50.4 kW cooling2,788 kWh/yr | 3 | $920 | |
| Toshiba MMY-MUP2001HT8P-A63 kW heating56 kW cooling3,023 kWh/yr | 3 | $998 | |
| Hitachi RAS-22FSXNS69 kW heating61.5 kW cooling5,715 kWh/yr | 1 | $1,886 |
Heat pumps similar to the Samsung Electronics AM200DXVGGR
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| LG ARUM201LTE663 kW heating56 kW cooling23,891 kWh/yr | 3 | $7,884 | |
| Mdv MV8-560WV2RN1E(MA)56 kW heating56 kW cooling35,492 kWh/yr | 2 | $11,712 | |
| LG ARUM200LTE563 kW heating56 kW cooling32,752 kWh/yr | 2.5 | $10,808 | |
| Toshiba MMY-MUP2001HT8P-A63 kW heating56 kW cooling3,023 kWh/yr | 3 | $998 | |
| Toshiba MMY-MAP2006FT8P-A56 kW heating56 kW cooling4,383 kWh/yr | 1.5 | $1,446 | |
| Carrier 38VT020188QTSG56 kW heating56 kW cooling2,761 kWh/yr | 4 | $911 | |
| Midea MV8-560WV2RN1E(MA)56 kW heating56 kW cooling35,492 kWh/yr | 2 | $11,712 | |
| Carrier 38VT020188HTSG63 kW heating56 kW cooling3,023 kWh/yr | 3 | $998 |
Compare AM200DXVGGR/SA with another model
Samsung Electronics AM200DXVGGR specifications
- Type
- Reverse cycle
- Configuration
- Multi-split / VRF
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 56.00 kW
- Cooling power input
- 17.48 kW
- Rated heating capacity (7 Β°C)
- 63.00 kW
- Heating power input
- 17.45 kW
- EER, full load (tested)
- 3.23
- COP, full load (tested)
- 3.64
- Rated AEER
- 3.20
- Rated ACOP
- 3.60
- Standby power (PIA)
- 13.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China, South Korea
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Samsung Electronics AM200DXVGGR zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 7,505 | 7,518 |
| Coldresidential | residential | 2.5 | 1.5 | 3,477 | 23,677 |
| Mixedcommercial | commercial | β | β | 9,519 | 3,782 |
| Mixedresidential | residential | 2.5 | 2.5 | 5,478 | 8,467 |
| Hotcommercial | commercial | β | β | 22,015 | 725 |
| Hotresidential | residential | 2.5 | 3.0 | 16,419 | 1,146 |
Part-load test points (24 values)
- h__h1_min_cap_power_rated
- 3150 W
- h__h2_ext_cap_power_rated
- 12490 W
- c__t1_half_cap_power_rated
- 6440 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 6270 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 14790 W
- h__h2_ext_cap_heat_cap_rated
- 45150 W
- h__h1_half_cap_heat_cap_rated
- 31500 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 2780 W
- c__low_temp_full_cap_power_rated
- 15976.720000000001 W
- c__low_temp_half_cap_power_rated
- 5886.16 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 28000 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 14890 W
- c__low_temp_full_cap_cooling_cap_rated
- 60312 W
- c__low_temp_half_cap_cooling_cap_rated
- 30156 W
New Zealand E3 registration details
- Registration number
- AAC7685
- GEMS registration id
- 155671
- Status
- approved, available (self-reported)
- Registration expires
- 6 August 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 21
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.