c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,883 kWh
261 cooling + 1,622 heating
Estimated running cost
$621 / year
$52 / month Β· $6,214 over 10 years
Capacity
5.2 kW cooling
5.2 kW heating

11% less electricity than the median of 20 comparable 5 kW reverse cycle fixed registrations (2,128 kWh a year) in the cold zone. Uses less than 85% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TCL TFM2-18CHD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,883$621$6,214
Mixed zone 1,001$330$3,303
Hot zone 1,249$412$4,122

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps similar to the TCL TFM2-18CHD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire H3M055S1AE5 kW heating5.2 kW cooling2,013 kWh/yr3.5$664
Hyundai HYSMHS52OTB5.2 kW heating5.2 kW cooling1,883 kWh/yr3.5$621
Bonaire H2M052S2AE5.2 kW heating5.2 kW cooling1,883 kWh/yr3.5$621
Toshiba RAS-2M18B2AVG-A5.6 kW heating5.2 kW cooling2,002 kWh/yr4$661
Mitsubishi Electric MXZ-2F52VGD6.1 kW heating5.2 kW cooling2,170 kWh/yr3.5$716
Hyundai HYSMHS52OTC5.2 kW heating5.2 kW cooling1,883 kWh/yr3.5$621
Kaden KM5.25.4 kW heating5.2 kW cooling2,057 kWh/yr3.5$679
Rinnai MON2H05B5.3 kW heating5.2 kW cooling2,041 kWh/yr3.5$674

Compare TFM2-18CHD/DVO with another model

TCL TFM2-18CHD specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.20 kW
Cooling power input
1.36 kW
Rated heating capacity (7 Β°C)
5.20 kW
Heating power input
1.15 kW
EER, full load (tested)
3.84
COP, full load (tested)
4.49
Rated AEER
3.76
Rated ACOP
4.44
Standby power (PIA)
6.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.9 dB(A)
Outdoor sound power
72 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TFM2-18CHD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––388515
Coldresidential3.52.52611,622
Mixedcommercial––579265
Mixedresidential3.53.0410591
Hotcommercial––1,37762
Hotresidential4.04.01,15495
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1340 W
c__t1_half_cap_power_rated
550 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
430 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4500 W
h__h1_half_cap_heat_cap_rated
2600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
380 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2600 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
2600 W

New Zealand E3 registration details

Registration number
AAC8810
GEMS registration id
169040
Status
approved, available (self-reported)
Registration expires
29 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19