New Zealand Β· costs in NZD

Reverse cycle window / wall air conditioner
TECO TWW28HVAG Heat Pump
TECO TWW28HVAG is a 2.8 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8323).
- Energy rating (cooling)
- 2
- Heating: 0.5
- Annual electricity use
- 1,735 kWh
- 202 cooling + 1,533 heating
- Estimated running cost
- $573 / year
- $48 / month Β· $5,726 over 10 years
- Capacity
- 2.8 kW cooling
- 2.4 kW heating
12% more electricity than the median of 21 comparable 2.5 kW reverse cycle window / wall registrations (1,546 kWh a year) in the cold zone. Uses less than 0% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 79% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
TECO TWW28HVAG running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,735 | $573 | $5,726 |
| Mixed zone | 863 | $285 | $2,848 |
| Hot zone | 963 | $318 | $3,178 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.8 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Euromatic EUR-9000WAC22.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Heller HWA272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Bonaire CRC60000272.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Kogan KAWDACR27TC2.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 | |
| Dimplex DCB092.4 kW heating2.7 kW cooling1,431 kWh/yr | 1.5 | $472 |
Heat pumps similar to the TECO TWW28HVAG
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kelvinator WH272.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Kelvinator KWH27HRF2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr | 2 | $510 | |
| Gree GJH09AK-K6NRNR1A2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Kaden KW092.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 | |
| Gree GJH09AK-K6NRNG2A2.5 kW heating2.8 kW cooling1,642 kWh/yr | 1.5 | $542 |
Compare TWW28HVAG with another model
TECO TWW28HVAG specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 2.80 kW
- Cooling power input
- 0.85 kW
- Rated heating capacity (7 Β°C)
- 2.43 kW
- Heating power input
- 0.77 kW
- EER, full load (tested)
- 3.38
- COP, full load (tested)
- 3.30
- Rated AEER
- 3.24
- Rated ACOP
- 3.10
- Standby power (PIA)
- 4.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 60.3 dB(A)
- Outdoor sound power
- 65.5 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
TECO TWW28HVAG zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 372 | 459 |
| Coldresidential | residential | 2.0 | 0.5 | 202 | 1,533 |
| Mixedcommercial | commercial | β | β | 483 | 239 |
| Mixedresidential | residential | 2.0 | 0.5 | 304 | 559 |
| Hotcommercial | commercial | β | β | 1,168 | 46 |
| Hotresidential | residential | 2.5 | 1.5 | 892 | 71 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 350 W
- h__h2_ext_cap_power_rated
- 659 W
- c__t1_half_cap_power_rated
- 420 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 330 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 1410 W
- h__h1_half_cap_heat_cap_rated
- 1220 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 280 W
- c__t1_min_cap_cooling_cap_rated
- 1160 W
- c__low_temp_full_cap_power_rated
- 776.9 W
- c__low_temp_half_cap_power_rated
- 383.88 W
- c__t1_half_cap_cooling_cap_rated
- 1450 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_min_cap_cooling_cap_rated
- 1390 W
- c__low_temp_full_cap_cooling_cap_rated
- 3015.6 W
- c__low_temp_half_cap_cooling_cap_rated
- 1561.6499999999999 W
New Zealand E3 registration details
- Registration number
- AAC8323
- GEMS registration id
- 160059
- Status
- approved, available (self-reported)
- Registration expires
- 2 July 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.