New Zealand Β· costs in NZD

Reverse cycle window / wall air conditioner
TECO TWW61HFWEG Heat Pump
TECO TWW61HFWEG is a 6.1 kW reverse cycle window / wall heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8178).
- Energy rating (cooling)
- 1.5
- Heating: 0.5
- Annual electricity use
- 3,964 kWh
- 510 cooling + 3,454 heating
- Estimated running cost
- $1,308 / year
- $109 / month Β· $13,081 over 10 years
- Capacity
- 6.1 kW cooling
- 5.8 kW heating
About the same electricity as the median of 7 comparable 6 kW reverse cycle window / wall registrations (3,964 kWh a year) in the cold zone. Uses less than 0% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
TECO TWW61HFWEG running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,964 | $1,308 | $13,081 |
| Mixed zone | 2,106 | $695 | $6,950 |
| Hot zone | 2,481 | $819 | $8,187 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 6.1 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MWFF53H4.8 kW heating5.4 kW cooling3,190 kWh/yr | 1.5 | $1,053 | |
| Kaden KW215.5 kW heating6 kW cooling3,734 kWh/yr | 1.5 | $1,232 | |
| Gree GJH21AE-K6NRNB3A5.7 kW heating6.1 kW cooling3,840 kWh/yr | 1.5 | $1,267 | |
| Gree GJH21AE-K6NRN**A5.7 kW heating6.1 kW cooling3,840 kWh/yr | 1.5 | $1,267 | |
| TECO TWW61HFWDG5.7 kW heating6.1 kW cooling3,840 kWh/yr | 1.5 | $1,267 |
Heat pumps similar to the TECO TWW61HFWEG
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kelvinator KWH60HRF5.8 kW heating6.1 kW cooling3,964 kWh/yr | 1.5 | $1,308 | |
| Westinghouse WWH60HWA5.8 kW heating6.1 kW cooling3,964 kWh/yr | 1.5 | $1,308 | |
| Gree GJH21AE-K6NRN**A5.7 kW heating6.1 kW cooling3,840 kWh/yr | 1.5 | $1,267 | |
| Kaden KW215.8 kW heating6.1 kW cooling3,964 kWh/yr | 1.5 | $1,308 | |
| Gree GJH21AE-K6NRNP1A5.7 kW heating6.1 kW cooling3,840 kWh/yr | 1.5 | $1,267 | |
| Westinghouse WH605.8 kW heating6.1 kW cooling3,964 kWh/yr | 1.5 | $1,308 | |
| Kaden KW215.5 kW heating6 kW cooling3,734 kWh/yr | 1.5 | $1,232 |
Other TECO models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| TECO TWW61HFWDG5.7 kW heating6.1 kW cooling3,840 kWh/yr | 1.5 | $1,267 |
Compare TWW61HFWEG with another model
TECO TWW61HFWEG specifications
- Type
- Reverse cycle
- Configuration
- Window / wall
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 6.09 kW
- Cooling power input
- 1.84 kW
- Rated heating capacity (7 Β°C)
- 5.80 kW
- Heating power input
- 1.77 kW
- EER, full load (tested)
- 3.37
- COP, full load (tested)
- 3.20
- Rated AEER
- 3.30
- Rated ACOP
- 3.26
- Standby power (PIA)
- 1.9 W
- Compressor
- Fixed speed
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 65.3 dB(A)
- Outdoor sound power
- 73 dB(A)
- Demand response (AS/NZS 4755)
- No
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
TECO TWW61HFWEG zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,187 | 1,079 |
| Coldresidential | residential | 1.5 | 0.5 | 510 | 3,454 |
| Mixedcommercial | commercial | β | β | 1,466 | 568 |
| Mixedresidential | residential | 1.5 | 0.5 | 773 | 1,333 |
| Hotcommercial | commercial | β | β | 3,168 | 114 |
| Hotresidential | residential | 1.5 | 1.0 | 2,297 | 184 |
Part-load test points (6 values)
- h__h2_full_cap_power_rated
- 1470 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 3450 W
- c__low_temp_full_cap_power_rated
- 1650 W
- c__low_temp_have_full_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 6350 W
New Zealand E3 registration details
- Registration number
- AAC8178
- GEMS registration id
- 160855
- Status
- approved, available (self-reported)
- Registration expires
- 15 April 2029
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 5
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.