c/kWh
Energy rating (cooling)
1.5
Heating: 1.5
Annual electricity use
16,096 kWh
2,520 cooling + 13,576 heating
Estimated running cost
$5,312 / year
$443 / month Β· $53,117 over 10 years
Capacity
31.5 kW cooling
31.3 kW heating

437% more electricity than the median of 12 comparable 35 kW reverse cycle ducted split system registrations (3,000 kWh a year) in the cold zone. Uses less than 8% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 8% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Temperzone ISD 351LYX running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 16,096$5,312$53,117
Mixed zone 8,881$2,931$29,307
Hot zone 12,104$3,994$39,943

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 31.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air SCA330C / SCG330E33 kW heating32 kW cooling2,779 kWh/yr1.5$917
Actron Air SCA340C / SCG340E35 kW heating32.5 kW cooling2,893 kWh/yr1.5$955
APAC S032OVR3SA- / S032IHR3SA-31.1 kW heating32.9 kW cooling2,917 kWh/yr1.5$963
APAC S032OVR3SA- / S032ILR3SA-31.1 kW heating32.9 kW cooling2,917 kWh/yr1.5$963

Heat pumps similar to the Temperzone ISD 351LYX

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air SCA330C / SCG330E33 kW heating32 kW cooling2,779 kWh/yr1.5$917
APAC S030OVR3SA / S030ILR3SA-FR26.5 kW heating32.1 kW cooling17,568 kWh/yr1.5$5,797
APAC S030OVR3SA / S030IVR3SA-TR26.5 kW heating32.1 kW cooling17,568 kWh/yr1.5$5,797
Actron Air SCA340C / SCG340E35 kW heating32.5 kW cooling2,893 kWh/yr1.5$955

Compare ISD 351LYX / OSA 352RLTFV with another model

Temperzone ISD 351LYX specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
31.48 kW
Cooling power input
10.02 kW
Rated heating capacity (7 Β°C)
31.29 kW
Heating power input
9.31 kW
EER, full load (tested)
3.14
COP, full load (tested)
3.36
Rated AEER
3.13
Rated ACOP
3.35
Standby power (PIA)
11.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, New Zealand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone ISD 351LYX zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6,5044,126
Coldresidential1.51.52,52013,576
Mixedcommercial––7,8492,108
Mixedresidential1.51.53,9064,975
Hotcommercial––15,961416
Hotresidential2.02.511,443661
Part-load test points (27 values)
c__t1_min_cap_power_rated
3700 W
h__h1_min_cap_power_rated
2700 W
h__h2_ext_cap_power_rated
11000 W
c__t1_half_cap_power_rated
4400 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
3600 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
8900 W
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
Yes
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
12000 W
h__h2_ext_cap_heat_cap_rated
26500 W
h__h1_half_cap_heat_cap_rated
15700 W
h__h2_full_cap_heat_cap_rated
22400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
3300 W
c__t1_min_cap_cooling_cap_rated
12100 W
c__low_temp_full_cap_power_rated
9158.28 W
c__low_temp_half_cap_power_rated
4100 W
c__t1_half_cap_cooling_cap_rated
15900 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
10700 W
c__low_temp_full_cap_cooling_cap_rated
33903.96 W
c__low_temp_half_cap_cooling_cap_rated
16500 W

New Zealand E3 registration details

Registration number
AAC8306
GEMS registration id
161550
Status
approved, available (self-reported)
Registration expires
19 June 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.