c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
8,061 kWh
1,081 cooling + 6,980 heating
Estimated running cost
$2,660 / year
$222 / month Β· $26,601 over 10 years
Capacity
16.4 kW cooling
17.3 kW heating

2% more electricity than the median of 6 comparable 16 kW reverse cycle ducted packaged registrations (7,887 kWh a year) in the cold zone. Uses less than 17% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 18% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Temperzone OPA 171RLTFY running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,061$2,660$26,601
Mixed zone 4,414$1,457$14,566
Hot zone 5,283$1,743$17,434

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 16.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air PRV15BT-T15 kW heating14.8 kW cooling6,723 kWh/yr2.5$2,219
AIRSTAGE RAQ/L/EC/WP/1513 kW heating14.9 kW cooling7,686 kWh/yr2$2,536
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling7,720 kWh/yr2.5$2,548

Heat pumps similar to the Temperzone OPA 171RLTFY

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
APAC P015AHR3SA-RBB14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
APAC P015AHR3SA14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
Actron Air PRV17AT-T18.4 kW heating17 kW cooling11,648 kWh/yr2$3,844
Daikin UAYN180AFY1A17.2 kW heating17.4 kW cooling10,894 kWh/yr1$3,595
AIRSTAGE RAQ/L/EC/WP/1513 kW heating14.9 kW cooling7,686 kWh/yr2$2,536
Actron Air PRV15BT-T15 kW heating14.8 kW cooling6,723 kWh/yr2.5$2,219

Other Temperzone models of similar capacity

ModelStarsEst. cost / yrCompare
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling7,720 kWh/yr2.5$2,548
Temperzone OPA161RKTY14.2 kW heating15.9 kW cooling7,937 kWh/yr1.5$2,619

Compare OPA 171RLTFY with another model

Temperzone OPA 171RLTFY specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
16.35 kW
Cooling power input
4.89 kW
Rated heating capacity (7 Β°C)
17.30 kW
Heating power input
5.05 kW
EER, full load (tested)
3.34
COP, full load (tested)
3.42
Rated AEER
3.30
Rated ACOP
3.38
Standby power (PIA)
18.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, New Zealand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone OPA 171RLTFY zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,1962,317
Coldresidential2.51.51,0816,980
Mixedcommercial––2,8381,261
Mixedresidential2.51.51,6752,739
Hotcommercial––6,359285
Hotresidential2.52.04,843440
Part-load test points (22 values)
h__h2_ext_cap_power_rated
6485 W
c__t1_half_cap_power_rated
2120 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2100 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
4748 W
h__h2_half_cap_power_rated
2060 W
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
Yes
h__h2_have_half_cap_results
Yes
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
17307 W
h__h1_half_cap_heat_cap_rated
8300 W
h__h2_full_cap_heat_cap_rated
14431 W
h__h2_half_cap_heat_cap_rated
7290 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
1780 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
8360 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
8880 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
OPA 171RLTFYAAC92192.57,720

New Zealand E3 registration details

Registration number
AAC8815
GEMS registration id
168273
Status
approved, available (self-reported)
Registration expires
30 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 6

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.